TXVFE-5-410A-CHATLEFF – EXPANSION VALVE (410, 5T, CHATLEFF)
Sanhua TXVFE-5-410A-CHATLEFF expansion valve. R-410A, 5-ton capacity, 3/8″ inlet, 1/2″ outlet. Chatleff fittings on both sides. For residential AC systems.
This is where you can browse products in this store.
Showing 1–48 of 67 results

Sanhua TXVFE-5-410A-CHATLEFF expansion valve. R-410A, 5-ton capacity, 3/8″ inlet, 1/2″ outlet. Chatleff fittings on both sides. For residential AC systems.

Supco SFL1402 safety locking valve caps, 2-pack. 1/4″ thermoplastic caps that lock onto refrigerant access valves. Meets code requirements for tamper-resistant caps.

Goodman B1225022S reversing valve solenoid coil, 24VAC, 50/60Hz, 5/4 watt. Controls the reversing valve on Goodman/Amana heat pump systems.

Goodman .052″ fixed orifice piston for 1.5-ton systems (R-410A). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

C&D CD2245 brass flare caps, 6-pack. 1/4″ with neoprene O-ring seal. Replace missing or damaged caps on refrigerant service valve ports to prevent leaks.

Sanhua 7/8″ ODF service valve (SERVICE-BAR-7-S-T). For refrigerant charging, vacuum pulling, and line isolation. Rated 650 PSI. Compatible with R-22 and R-410A.

Supco SFL1410 safety locking valve caps, 10-pack. 1/4″ thermoplastic caps that lock onto refrigerant access valves. Meets code requirements for tamper-resistant caps.

Goodman B1225017 reversing valve solenoid coil, 24V, 5 watt. Controls the reversing valve on Goodman/Amana heat pump systems to switch between heating and cooling.

R-410A refrigerant, 25 lb cylinder. Standard refrigerant for residential AC systems built since 2010. Higher pressure than R-22 — use only in R-410A rated equipment.

Sanhua TXVFE-4-410A-CHATLEFF expansion valve. R-410A, 4-ton capacity, 3/8″ inlet, 1/2″ outlet. Chatleff fittings on both sides. For residential AC systems.

Goodman .065″ fixed orifice piston for 2.5-ton systems (R-410A and R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman B1796630 / BT1369063 90-degree stub elbow fitting. Connects the piston assembly to the refrigerant line. OEM Goodman/Amana part.

3/4″ sweat suction line filter drier, 16 cu. in. Installed on the suction side after a compressor burnout to remove acid and debris. Protects the new compressor.

Nu-Calgon EasySeal 4050-11 refrigerant leak sealant with UV dye. Treats 2 to 7.5 ton systems. Works with all refrigerant types. Direct-inject installation.

Goodman .093″ fixed orifice piston for 5-ton systems (R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

C&D CD2028 brass adapter. 1/4″ male flare to 1/2″ female Acme swivel with depressor. Adapts R-134a automotive fittings to standard 1/4″ HVAC connections.

Goodman .055″ fixed orifice piston for 2-ton R-410A / 1.5-ton R-22 systems (R-410A and R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Sanhua TXVFE-4-22-KIT expansion valve. R-22, 4-ton capacity, 3/8″ inlet, 1/2″ outlet. Includes both Aeroquip and Chatleff fittings for flexible installation. For residential AC systems.

7/8″ sweat suction line filter drier, 16 cu. in. Installed on the suction side after a compressor burnout to remove acid and debris. Protects the new compressor.

Goodman .082″ fixed orifice piston for 4-ton systems (R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .071″ fixed orifice piston for 3.5-ton systems (R-410A). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .074″ fixed orifice piston for 3-ton systems (R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Sanhua TXVFE-5-410A-KIT expansion valve. R-410A, 5-ton capacity, 3/8″ inlet, 1/2″ outlet. Includes both Aeroquip and Chatleff fittings for flexible installation. For residential AC systems.

Sanhua TXVFE-2-410A-KIT expansion valve. R-410A, 2-ton capacity, 3/8″ inlet, 1/2″ outlet. Includes both Aeroquip and Chatleff fittings for flexible installation. For residential AC systems.

Sanhua sight glass, 3/8″ sweat connections. Lets you see refrigerant flow and check moisture levels in the liquid line. Color indicator changes if moisture is present.

R-407C refrigerant, 25 lb cylinder. R-22 replacement for existing air conditioning systems. Blend of R-32, R-125, and R-134a. No oil change needed in most systems.

3/8″ sweat bi-flow filter drier, 16 cu. in. Works in both directions — made for heat pump systems. Removes moisture and acid. Compatible with all common refrigerants.

Supco SFL1450 safety locking valve caps, 50-pack. 1/4″ thermoplastic caps that lock onto refrigerant access valves. Contractor bulk pack — meets code requirements.

LG APG025KAC scroll compressor, 2.5 ton, R-410A. Direct replacement for Copeland ZP25K5E series. Common mid-size residential AC compressor.

LG APG031KAC scroll compressor, 3 ton, R-410A. Direct replacement for Copeland ZP31K5E and ZP29LXE series. The most common residential tonnage.

R-454B refrigerant, 20 lb cylinder. Low-GWP replacement for R-410A in new systems. A2L mildly flammable — requires proper handling. The future of residential AC refrigerant.

C&D CD2012 brass coupler. 1/4″ female flare swivel to 1/2″ male Acme with depressor. Adapts R-134a automotive fittings to standard 1/4″ HVAC connections.

Sanhua TXVFE-2-22-KIT expansion valve. R-22, 2-ton capacity, 3/8″ inlet, 1/2″ outlet. Includes both Aeroquip and Chatleff fittings for flexible installation. For residential AC systems.

Sanhua 3/4″ ODF service valve (SERVICE-BAR-6-S-T). For refrigerant charging, vacuum pulling, and line isolation. Rated 650 PSI. Compatible with R-22 and R-410A.

R-438A (MO99) refrigerant, 25 lb cylinder. Drop-in replacement for R-22 — no oil change, no metering device change, no TXV adjustment needed in most systems.

Yellow Jacket 19124 left-hand thread adapter for A2L refrigerants. 1/4″ LH female flare to 1/4″ RH male flare. Required for servicing R-32 and R-454B systems.

Supco BPV21 Bullet piercing valve for 1/2″ and 5/8″ OD tubing. Clamps onto sealed lines to add a service access port — no brazing needed. Patented gasket seal.

Sanhua TXVFE-6-410A-CHATLEFF expansion valve. R-410A, 6-ton capacity, 3/8″ inlet, 1/2″ outlet. Chatleff fittings on both sides. For residential AC systems.

Goodman .090″ fixed orifice piston for 5-ton systems (R-410A). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

LG ABG036KAC scroll compressor, 3.5 ton, R-410A. Direct replacement for Copeland ZP36K5E and ZP37LXE series. Used in Rheem, Goodman, and other systems.
![CD9601/2 - TEE FITTING ([1] 1/4F to [2] 1/4M) (PACK OF 2)](https://otp-hvac.com/wp-content/uploads/2024/11/CD9601_SERVICE_VALVE_TEE_FITTING-300x300.png)
C&D CD9601/2 brass tee fitting, 2-pack. 1/4″ female flare with depressor to two 1/4″ male flare ports (one with valve core). Adds a branch access point to refrigerant lines.

Goodman .078″ fixed orifice piston for 4-ton R-410A / 3.5-ton R-22 systems (R-410A and R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Mastercool 62010 refrigerant recovery tank, 30 lb capacity. Steel construction with Y-valve design. DOT approved. Not rated for A2L refrigerants.

3/8″ sweat liquid line filter drier, 16 cu. in., uni-flow. Removes moisture and acid from the refrigerant line. Works with R-22, R-410A, and other common refrigerants.

Goodman .059″ fixed orifice piston for 2-ton R-22 / 2.5-ton R-410A systems (R-22 and R-410A). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

C&D CD1454/2 brass fitting, 2-pack. 1/4″ female flare to 1/4″ male flare with installed valve core. Adds a Schrader core to a port that doesn’t have one.

Sanhua TXVFE-5-22-KIT expansion valve. R-22, 5-ton capacity, 3/8″ inlet, 1/2″ outlet. Includes both Aeroquip and Chatleff fittings for flexible installation. For residential AC systems.

Sanhua TXVFE-3-410A-KIT expansion valve. R-410A, 3-ton capacity, 3/8″ inlet, 1/2″ outlet. Includes both Aeroquip and Chatleff fittings for flexible installation. For residential AC systems.