CD2245 – BRASS CAP (1/4″, 6/PKG)
The cap is the real seal on a service port - the Schrader core is a valve, not a seal. Put the caps back on, with their gaskets. And if you are working on A2L, remember the tank connection is left-hand threaded and needs the reverse adaptor.
10226 Plano Rd, Suite 104, Dallas TX 75238
Questions? Call or text (214) 340-9421
Mon–Fri 10 am – 7 pm | Sat 10 am – 3 pm
Brass flare caps seal refrigerant service valve ports when they’re not being used. If a cap is missing or the O-ring is worn, you’ll get a slow refrigerant leak over time. These 1/4″ caps come with neoprene O-rings for a tight seal. Keep a pack on hand — they go missing all the time.
Specs: 1/4″ brass flare caps, neoprene O-ring seal, 6-pack
Replaces: 83-CD2245-6PK, CD2245, CD2245-6PK
Fits: Standard 1/4″ SAE flare refrigerant service valve ports on all HVAC brands.
In stock at Open To Public HVAC Parts in Dallas. We test parts at the counter before you buy. Call or text (214) 340-9421.
Specs
- TypeService port cap
- Size1/4"
- MaterialBrass
- Quantity6 per pack
- NoteThe cap is the primary seal, not the Schrader core
Cross-reference numbers
This part replaces the following OEM and aftermarket numbers:
- 83-CD2245-6PK
- CD2245
- CD2245-6PK
- CDVALVECD22456
Not sure if your number matches? Call (214) 340-9421 or bring the old part in — bench-testing is free.
Fits these models
- CDVALVECD224525
- CDVALVECD22452514FLAREBRASSCAPPACKOF25
- CDVALVECD2245614FLAREBRASSCAPPACKOF6
What size are HVAC service fittings?
1/4 inch flare is the standard service port on residential equipment. Most of the adaptors and caps here step between 1/4 inch and other sizes so you can connect gauges, a recovery machine or a vacuum pump.
Why do I need a left-hand thread adaptor?
A2L refrigerants - R-454B and R-32 - use LEFT-HAND (reverse) threaded cylinder connections. It is a deliberate keying change so A2L equipment cannot be cross-connected to older refrigerant. Without the adaptor a standard hose simply will not start on the tank.
Does the cap actually matter?
Yes. The cap is the primary seal on a service port, not the Schrader core. The core is a valve; the cap with its gasket is what holds refrigerant in over years. A missing cap is a slow leak you will not find with a sniffer for a long time.
What is a core removal tool for?
Taking the Schrader core out so you can pull a proper vacuum through a full-bore path instead of through a tiny valve. On anything bigger than a small system it is the difference between a real vacuum and a long afternoon.
Male or female - how do I tell?
Male threads are on the outside of the fitting, female on the inside. The listings here spell out each end, for example 1/4" male to 1/2" female, so you can match what you already have.
Do you stock these?
On the shelf at 10226 Plano Rd, Suite 104 in Dallas.