0151R00069SP – REVERSING VALVE W/ SOLENOID COIL & DRIER (3/4″ x 1/2″)
Goodman / Amana heat pump reversing valve service pack, supplied with the solenoid coil and a filter drier.
Everything you need for the refrigeration side of your air conditioning system. Shop refrigerant (R-22, R-410A, R-407C), line sets, service valves, filter driers, TXV valves, sight glasses, and charging hoses at our Dallas walk-in store.EPA Section 608 certification is required to purchase refrigerant. We carry the gauges, hoses, vacuum pumps, and leak detection tools you need for a proper charge. Serving HVAC contractors and certified DIYers across Dallas-Fort Worth since 1998.
All refrigeration supplies are sold in-store only — no shipping. Bring your EPA card for refrigerant and pick everything up the same day.
Showing 1–48 of 90 results

Goodman / Amana heat pump reversing valve service pack, supplied with the solenoid coil and a filter drier.

Goodman reversing valve with 24V solenoid coil and bi-flow filter drier. 7/8″ x 1/2″ connections. Complete assembly for heat pump systems.

90-degree quick coupler for refrigeration service work.

Yellow Jacket 19124 left-hand thread adapter for A2L refrigerants. 1/4″ LH female flare to 1/4″ RH male flare. Required for servicing R-32 and R-454B systems.

Carrier TXV kit, Danfoss TR 6, OEM number EA36YD046, rated 3.60 TR and approved for both R-22 and R-407C. Chatleff / braze connections, supplied with bulb and hardware.

Nu-Calgon EasySeal 4050-11 refrigerant leak sealant with UV dye. Treats 2 to 7.5 ton systems. Works with all refrigerant types. Direct-inject installation.

Rheem/Protech service part, listed by the factory parts catalog as a Sporlan BBIZE-5-GA expansion valve, rated for R-410A at 5 tons.

Mastercool 62010 refrigerant recovery tank, 30 lb capacity. Steel construction with Y-valve design. DOT approved. Not rated for A2L refrigerants.

Mastercool 63010 refrigerant recovery tank, 50 lb capacity. Steel construction with Y-valve design. DOT approved. Not rated for A2L refrigerants.

Nortek TR 6 thermal expansion valve for R-410A, rated 4.00 TR (four tons). Danfoss-built, code 067U3031, UL listed, 711 psig maximum working pressure.

LG ABG036KAC scroll compressor, 3.5 ton, R-410A. Direct replacement for Copeland ZP36K5E and ZP37LXE series. Used in Rheem, Goodman, and other systems.

LG ABG042KAC scroll compressor, 4 ton, R-410A. Direct replacement for Copeland ZP42K5E and ZP40K6E series. Fits Carrier, Rheem, Goodman, and others.

LG hermetic scroll compressor for R-410A. LG’s nomenclature codes the leading A as an R-410A low-side-shell scroll, and its catalog lists the ABG051KA as a single-phase 208-230 V fixed-speed HVAC model.

LG ABH051KAA scroll compressor, 5 ton, R-410A. Direct replacement for Copeland ZP51K5E series. For large residential and light commercial AC systems.

LG APG021KBC scroll compressor, 2 ton, R-410A. Direct replacement for Copeland ZP21K5E series. Common in smaller residential AC systems.

LG APG025KAC scroll compressor, 2.5 ton, R-410A. Direct replacement for Copeland ZP25K5E series. Common mid-size residential AC compressor.

LG APG031KAC scroll compressor, 3 ton, R-410A. Direct replacement for Copeland ZP31K5E and ZP29LXE series. The most common residential tonnage.


Goodman B1225017 reversing valve solenoid coil, 24V, 5 watt. Controls the reversing valve on Goodman/Amana heat pump systems to switch between heating and cooling.

Goodman B1225022S reversing valve solenoid coil, 24VAC, 50/60Hz, 5/4 watt. Controls the reversing valve on Goodman/Amana heat pump systems.

Goodman .052″ fixed orifice piston for 1.5-ton systems (R-410A). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .055″ fixed orifice piston for 2-ton R-410A / 1.5-ton R-22 systems (R-410A and R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .059″ fixed orifice piston for 2-ton R-22 / 2.5-ton R-410A systems (R-22 and R-410A). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .065″ fixed orifice piston for 2.5-ton systems (R-410A and R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .068″ fixed orifice piston for 3-ton systems (R-410A). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .071″ fixed orifice piston for 3.5-ton systems (R-410A). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .074″ fixed orifice piston for 3-ton systems (R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .078″ fixed orifice piston for 4-ton R-410A / 3.5-ton R-22 systems (R-410A and R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .082″ fixed orifice piston for 4-ton systems (R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .090″ fixed orifice piston for 5-ton systems (R-410A). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman .093″ fixed orifice piston for 5-ton systems (R-22). Controls refrigerant flow in Goodman and Amana condensers. OEM part.

Goodman B1796630 / BT1369063 90-degree stub elbow fitting. Connects the piston assembly to the refrigerant line. OEM Goodman/Amana part.

Goodman B1796632 piston nut and Teflon seal. Secures the piston in the refrigerant line and prevents leaks. OEM Goodman/Amana replacement.

Supco BPV21 Bullet piercing valve for 1/2″ and 5/8″ OD tubing. Clamps onto sealed lines to add a service access port — no brazing needed. Patented gasket seal.

Supco BPV31 Bullet piercing valve for 1/4″, 5/16″, and 3/8″ OD tubing. Clamps onto sealed lines to add a service access port — no brazing needed. Patented gasket seal.

C&D CD1454/2 brass fitting, 2-pack. 1/4″ female flare to 1/4″ male flare with installed valve core. Adds a Schrader core to a port that doesn’t have one.

C&D CD2012 brass coupler. 1/4″ female flare swivel to 1/2″ male Acme with depressor. Adapts R-134a automotive fittings to standard 1/4″ HVAC connections.

C&D CD2028 brass adapter. 1/4″ male flare to 1/2″ female Acme swivel with depressor. Adapts R-134a automotive fittings to standard 1/4″ HVAC connections.

C&D CD2245 brass flare caps, 6-pack. 1/4″ with neoprene O-ring seal. Replace missing or damaged caps on refrigerant service valve ports to prevent leaks.
![CD9601/2 - TEE FITTING ([1] 1/4F to [2] 1/4M) (PACK OF 2)](https://otp-hvac.com/wp-content/uploads/2024/11/CD9601_SERVICE_VALVE_TEE_FITTING-300x300.png)
C&D CD9601/2 brass tee fitting, 2-pack. 1/4″ female flare with depressor to two 1/4″ male flare ports (one with valve core). Adds a branch access point to refrigerant lines.

24VAC solenoid coil for Sanhua SHF-series reversing valves. Controls the reversing valve on heat pump systems to switch between heating and cooling. Spade terminals.

Copeland hermetic reciprocating compressor from the CR__KQ(E) family. Copeland bulletin AE4-1329 approves this family for R-22 and R-407C in air conditioning and heat pump duty, with an IPR valve, internal line-break motor protection and 1/4 in. quick-connect or molded-plug terminals.

Uniweld Ez-Turn anti-blowback mini split adapter. Converts a 1/4 in. male flare service port to the 5/16 in. (1/2-20) female fitting used on R-410A mini split service valves, and the gas-retaining design holds charge while you connect.

3/8″ sweat bi-flow filter drier, 16 cu. in. Works in both directions — made for heat pump systems. Removes moisture and acid. Compatible with all common refrigerants.

1/4″ threaded liquid line drier for refrigerant recovery machines. Solid core design removes moisture and acid. Compatible with all refrigerants.

PRO*PARTS PP-COM-LEADS-8 compressor lead kit. Three 10 AWG THHN leads with sealed heat-shrink butt connectors, 600V rated.

R-32 refrigerant in a 20 lb cylinder. R-32 is a lower-GWP A2L refrigerant used in newer equipment – EPA Section 608 certification and A2L-rated handling practices apply, and an A2L tank adaptor is needed to connect standard gauges.

R-404A refrigerant, 24 lb cylinder. Used in commercial refrigeration — walk-in coolers, freezers, reach-in units, and ice machines. Not for residential AC.