50DK406815 – INDUCER ASSEMBLY (AFTERMARKET, DIRECT, 66649)
Aftermarket inducer assembly for Carrier furnaces. 208-230V, 3450 RPM. Replaces 50DK406815. Complete assembly with motor, housing, and wheel. Packard 66649.
This is where you can browse products in this store.
Showing 1–48 of 129 results

Aftermarket inducer assembly for Carrier furnaces. 208-230V, 3450 RPM. Replaces 50DK406815. Complete assembly with motor, housing, and wheel. Packard 66649.

Aftermarket inducer motor assembly for Carrier furnaces. Two-speed, thermally protected. Replaces 326628-761 and multiple cross-references. Complete assembly by Packard (66761).

20″ aluminum 3-blade condenser fan blade. 28° pitch, CW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

3/4 HP Genteq Evergreen variable-speed ECM blower motor. 120/240V dual voltage, 1050 RPM, 4-pin control. Direct replacement for Genteq 2.3 and 3.0 ECM motors.

1-1/3 HP universal ECM blower motor by U.S. Motors. 115/230V dual voltage, 1075 RPM. Replaces 16-pin variable speed models including EON and Nidec ECMs.

Aftermarket two-speed inducer motor for Carrier/Bryant furnaces. 115V, direct replacement for HC21ZE118. Also replaces HC21ZE116. Motor only — reuse existing housing.

22″ aluminum 3-blade condenser fan blade. 27° pitch, CW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

3/4 to 1/5 HP furnace blower motor, 115V, 1075 RPM, multi-speed reversible. Requires 15 MFD capacitor. Fits Trane, Carrier, and other 115V furnaces.

1/4 HP air handler blower motor, 208-230V, 1075 RPM, 3-speed reversible. Requires 10 MFD capacitor. The 230V version for air handlers that need a 1/4 HP motor.

1/3 to 1/5 HP condenser fan motor, 1075 RPM, 208-230V, 10 MFD cap. Multi-HP replacement for Goodman, Trane, Carrier, Lennox, and more.

20″ aluminum 3-blade condenser fan blade. 31° pitch, CCW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

Aftermarket inducer blower wheel for Carrier/Bryant furnaces. Clockwise rotation, 3.82″ diameter, 5/16″ bore. Replaces LA11XA048.

Aftermarket inducer motor assembly for Carrier furnaces. Replaces 349336-762 and 326628-762. Complete assembly with motor, housing, and wheel. Packard 66762.

Aftermarket inducer blower wheel for Carrier/Bryant furnaces. 4.5″ diameter, 1.65″ width, CCW rotation. Replaces LA11XA046. Cheaper fix than replacing the whole assembly.

22″ aluminum 4-blade condenser fan blade. 27° pitch, CW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

Nortek 622686 ECM blower motor — 1/2 HP, 1050 RPM, 208-230V, 48-frame. Variable speed with proprietary PWM harness. Direct replacement for 622686R.

1/3-1/5 HP 2-speed condenser fan motor, 1075 RPM, 208-230V, 5 MFD cap. Ball bearings with reversible rotation. Fits multiple residential condensers.

York OEM 1 HP double-shaft blower motor. 115V, 1100 RPM, 4-speed. Direct fit for York furnaces and air handlers. Replaces F48E34A48 and S83-536.

Goodman B1376857 motor mount arms, set of 3. OEM replacement for Goodman and Amana furnaces and air handlers. Secures the blower motor in the housing.

1/4-1/8 HP 825 RPM condenser fan motor, 208-230V, 48-frame, 5 or 7.5 MFD cap. Multi-HP motor with reversible rotation and overload protection.

Fasco D258 double-shaft blower motor. 1/5 to 1/10 HP, 1550 RPM, 208-230V. 5-inch diameter with resilient ring mount, sleeve bearings, and auto overload protection.

Fasco 4C2227CCW condenser fan blade — 22″, 4-blade, 27° pitch, CCW rotation, hubless. Cross-references Revcor R42207 and Lau 60559401.

20″ aluminum 4-blade condenser fan blade. 23° pitch, CCW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

18″ aluminum 4-blade condenser fan blade. 23° pitch, CCW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

Aftermarket inducer motor for Goodman furnaces. 115V, 3000 RPM, 1/40 HP. Replaces B1859005. Complete assembly with motor, wheel, housing, and gasket.

Rheem AE-58384-81 screw shell motor mount kit, 4-arm. OEM replacement for mounting 48-frame blower motors in Rheem and Ruud furnaces and air handlers.

18″ aluminum 3-blade condenser fan blade. 33° pitch, CW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

12″ x 12″ clockwise blower wheel with concave blades and 1/2″ bore. OEM Carrier/Bryant/Payne part 1176937. For larger tonnage air handlers.

Carrier OEM inducer cooling fan wheel. Part 326100-401, also listed as LA660003. Cools the inducer motor during operation. Replace if cracked or wobbling.

10″ x 10″ counter-clockwise blower wheel with concave blades and 1/2″ bore. OEM Goodman part. Replaces Rheem 70-23110-30.

Aftermarket inducer motor for Rheem/Ruud furnaces. 120V, 3000 RPM, 1/30 HP. Replaces 70-24157-03. Right-side discharge. Complete assembly.

1/3-1/6 HP 2-speed condenser motor, 825 RPM, 208-230V. Trane mounting configuration. Replaces Trane and other brand condenser fan motors.

1/3-1/5 HP 2-speed condenser fan motor, 825 RPM, 208-230V, 7.5 MFD cap. Reversible rotation with thermal overload protection.

20″ aluminum 4-blade condenser fan blade. 33° pitch, CW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

Aftermarket inducer motor assembly for ICP/Heil/Tempstar furnaces. 115V, 1.6A. Replaces 1013833. Complete assembly with motor, housing, and wheel.

Goodman OEM draft inducer motor. 1/50 HP, 115V, 3000 RPM. Direct replacement for Goodman/Amana furnaces using part B1859000 or 82483. Includes motor only — reuse your existing housing.

18″ aluminum 3-blade condenser fan blade. 27° pitch, CCW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

Goodman OEM draft inducer motor. 120V, 3000 RPM. Direct replacement part 0131G00000PS. OEM quality for Goodman and Amana furnaces.

11.75″ x 10.75″ clockwise blower wheel with convex blades. OEM Carrier/Bryant/Payne part. Replaces LA22ZA117 and LA22ZA117A.

20″ aluminum 3-blade condenser fan blade. 28° pitch, CCW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

1/2 to 1/6 HP air handler blower motor, 208-230V, 1075 RPM with reversible rotation. Requires 10 MFD capacitor. Thermal overload protection built in.

Carrier OEM inducer motor gasket kit. Seals the inducer motor housing to prevent exhaust gas leaks. Use when replacing the inducer motor or if you smell exhaust fumes near the furnace.

1/2″ to 5/8″ motor shaft bushing. Adapts a 1/2″ motor shaft to fit a 5/8″ bore blower wheel or pulley. Steel with keyway slot.

20″ aluminum 4-blade condenser fan blade. 23° pitch, CCW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

3/4 HP ECM X13 constant-torque blower motor, 115/208-230V dual voltage. Replaces multiple Goodman, Trane, and Lennox X13 motors. Preprogrammed with harness.

3/4 HP air handler blower motor, 208-230V, 1075 RPM, 4-speed reversible. Requires 10 MFD 370V capacitor (sold separately). The 230V version of the EM3466.

20″ aluminum 4-blade condenser fan blade. 27° pitch, CW rotation, hubless (no hub). Replacement for HVAC condenser and heat pump units.

Aftermarket inducer motor for Lennox furnaces. 120V, 3000 RPM, 1/60 HP. Replaces 85L49. Complete assembly with motor, wheel, housing, and gaskets.