BPV31 – PIERCING VALVE (1/4″, 5/16″, 3/8″)
The cap is the real seal on a service port - the Schrader core is a valve, not a seal. Put the caps back on, with their gaskets. And if you are working on A2L, remember the tank connection is left-hand threaded and needs the reverse adaptor.
10226 Plano Rd, Suite 104, Dallas TX 75238
Questions? Call or text (214) 340-9421
Mon–Fri 10 am – 7 pm | Sat 10 am – 3 pm
A piercing valve clamps onto a sealed copper refrigerant line and punctures a small hole to create a service access port — no brazing needed. The BPV31 fits 1/4″, 5/16″, and 3/8″ OD tubing with a patented gasket seal.
Specs: Fits 1/4″, 5/16″, 3/8″ OD tubing, clamp-on, no brazing, patented gasket seal
Replaces: BPV31, QTM-1, QTM1, STV-1, STV1
Fits: 1/4″, 5/16″, and 3/8″ OD copper refrigerant tubing. Universal — all HVAC brands.
In stock at Open To Public HVAC Parts in Dallas. We test parts at the counter before you buy. Call or text (214) 340-9421.
Specs
- TypeService valve fitting or adaptor
Cross-reference numbers
This part replaces the following OEM and aftermarket numbers:
- 38
- 516
- AP4502525
- BPV31D
- GPV14
- GPV31
- GPV38
- GPV56
- MPV31
- QTM-1
- QTM1
- STV-1
- STV1
- SUPCOBPV31
Not sure if your number matches? Call (214) 340-9421 or bring the old part in — bench-testing is free.
Fits these models
- COMPATIBLEWITHAP4502525
- SUPCOBPV31BULLETPIERCINGVALVE14
What size are HVAC service fittings?
1/4 inch flare is the standard service port on residential equipment. Most of the adaptors and caps here step between 1/4 inch and other sizes so you can connect gauges, a recovery machine or a vacuum pump.
Why do I need a left-hand thread adaptor?
A2L refrigerants - R-454B and R-32 - use LEFT-HAND (reverse) threaded cylinder connections. It is a deliberate keying change so A2L equipment cannot be cross-connected to older refrigerant. Without the adaptor a standard hose simply will not start on the tank.
Does the cap actually matter?
Yes. The cap is the primary seal on a service port, not the Schrader core. The core is a valve; the cap with its gasket is what holds refrigerant in over years. A missing cap is a slow leak you will not find with a sniffer for a long time.
What is a core removal tool for?
Taking the Schrader core out so you can pull a proper vacuum through a full-bore path instead of through a tiny valve. On anything bigger than a small system it is the difference between a real vacuum and a long afternoon.
Male or female - how do I tell?
Male threads are on the outside of the fitting, female on the inside. The listings here spell out each end, for example 1/4" male to 1/2" female, so you can match what you already have.
Do you stock these?
On the shelf at 10226 Plano Rd, Suite 104 in Dallas.