Carrier OEM inducer cooling fan wheel. Part 326100-401, also listed as LA660003. Cools the inducer motor during operation. Replace if cracked or wobbling.
Goodman 4053501S draft inducer vent kit. Includes the vent pipe and fittings for the inducer motor assembly. Use when replacing the inducer or repairing the exhaust vent connection.
Aftermarket inducer motor for Coleman/York furnaces. 1/150 HP, 115V, 3315 RPM. Direct replacement for S1-37319801821. Ball bearing motor for longer life.
Aftermarket inducer motor assembly for Carrier furnaces. Two-speed, thermally protected. Replaces 326628-761 and multiple cross-references. Complete assembly by Packard (66761).
Aftermarket inducer motor assembly for Carrier furnaces. 115V, 3200 RPM. Direct replacement for 310371-752. Includes motor, housing, wheel, and gasket — complete swap.
Goodman OEM draft inducer motor. 1/50 HP, 115V, 3000 RPM. Direct replacement for Goodman/Amana furnaces using part B1859000 or 82483. Includes motor only — reuse your existing housing.
Aftermarket inducer motor assembly for Trane/American Standard furnaces. 115V, 3000 RPM, 1/50 HP. Replaces BLW00889. Complete assembly with motor, wheel, housing, and gaskets.
Aftermarket inducer motor assembly for Rheem/Ruud furnaces. 115V, 3000 RPM. Replaces 70-101087-81 and 70-24175-01. Complete assembly with motor, housing, and wheel.
Draft inducer assembly for ICP / Heil-Tempstar gas furnaces. Fasco’s published draft inducer cross-reference lists ICP 1014529 – alongside 1014433 and FB-RFB433, and Fasco originals 119290-00 and 119290-01 – as served by Fasco A983, which confirms the application family.
Aftermarket inducer motor for Lennox furnaces. 1/30 HP, 115V, 3000 RPM. Direct replacement for Lennox 24W95 and 31L55. Includes motor, housing, wheel, and gasket.
Carrier OEM inducer motor gasket kit. Seals the inducer motor housing to prevent exhaust gas leaks. Use when replacing the inducer motor or if you smell exhaust fumes near the furnace.
Aftermarket inducer blower wheel for Carrier/Bryant furnaces. Replaces LA660002. Use when the wheel is cracked, chipped, or wobbling — no need to replace the whole motor.
Draft inducer motor for Carrier, Bryant and Payne gas furnaces, recorded internally as 1183450. The inducer motor drives the combustion blower that purges the heat exchanger and pulls flue products through the vent, and its operation is what the furnace pressure switch proves before ignition.
Packard 66753 inducer motor assembly for Carrier furnaces. Replaces 318984-753. Complete assembly with motor, bracket, and blower wheel — everything you need for a full swap.
Aftermarket inducer motor for Carrier furnaces. 115V, 1/25 HP, 3300 RPM. Replaces 318984-753, HC21ZE114, HC21ZE117, and HC21ZE123. Fits a wide range of Carrier models.
Aftermarket inducer motor assembly for Carrier furnaces. Replaces 349336-762 and 326628-762. Complete assembly with motor, housing, and wheel. Packard 66762.
Aftermarket two-speed inducer motor for Carrier/Bryant furnaces. 115V, direct replacement for HC21ZE118. Also replaces HC21ZE116. Motor only — reuse existing housing.
Aftermarket inducer assembly for Carrier furnaces. 208-230V, 3450 RPM. Replaces 50DK406815. Complete assembly with motor, housing, and wheel. Packard 66649.
Signs You May Need a New Inducer Motor
The inducer (draft) motor is the small fan that runs at the very beginning of the furnace heating cycle. It pulls combustion gases through the heat exchanger and out the flue.
⛔Furnace Won't Start — No Ignition Attempt▼
The furnace doesn't attempt to light at all when the thermostat calls for heat.
The inducer motor should be the first thing you hear — a quiet whirring sound.
If you don't hear it, the control board can't proceed to the ignition step.
🔊Loud or Unusual Noises at Startup▼
A loud humming, rattling, or grinding noise when the furnace starts.
Screeching or squealing that indicates worn bearings.
These sounds typically get worse over weeks and indicate imminent failure.
💨Inducer Runs but Furnace Doesn't Light▼
You can hear the inducer motor running but ignition never happens.
The pressure switch may not be closing because the inducer isn't pulling enough draft.
A partially failed motor may spin but not generate sufficient airflow.
🔄Furnace Short-Cycles Before Completing Heat Cycle▼
Furnace starts the cycle, runs briefly, then shuts down.
A failing inducer can cause pressure switch faults mid-cycle.
The control board shuts everything down as a safety measure.
Not sure which part you need? Bring your old part to our Dallas store — our team will test it for free and help you find the right replacement. 📞 (214) 340-9421Mon–Fri 10 am – 7 pm | Sat 10 am – 3 pm