CNT07737 – CONTROL BOARD (OEM, TRANE, CONSTANT TORQUE)
Trane CNT07737 OEM control board for furnaces with constant torque motors. Replaces CNT04711. Fits TUD1C series and similar Trane/American Standard models.
This is where you can browse products in this store.
Showing 1–48 of 81 results

Trane CNT07737 OEM control board for furnaces with constant torque motors. Replaces CNT04711. Fits TUD1C series and similar Trane/American Standard models.

Carrier HK32EA007 defrost control board for heat pumps. Manages defrost cycles to prevent coil freezing. Replaces HK32EA001. OEM Carrier/Bryant/Payne.

Goodman PCBBF112S control board (50A55-743 aftermarket). Fits GMS80 series Goodman gas furnaces. Direct replacement for B18099-26 and 0130F00005.

Rheem 47-102684-204 defrost control board for heat pumps. Manages defrost timing to prevent ice buildup on outdoor coil. OEM Rheem/Ruud replacement.

Carrier/Bryant/Payne OEM ignition control board. Carrier publishes no public specification sheet for this part to non-dealers, and no manufacturer cross-reference could be verified, so no electrical ratings are stated here.

Rheem RH2TZ6024STANNJ 5-ton air handler. Constant Torque ECM motor, R-410A compatible, SEER2 compliant. 24″ wide cabinet with multiple installation options.

Rheem/Ruud ProTech genuine OEM integrated furnace control (IFC) board. It manages the heating sequence from gas ignition through blower off-delay and reports faults through an onboard LED.

ICM Controls ICM2812 hot surface ignition furnace control board, published by ICM as a board-only replacement for the White-Rodgers 50M56U-843. It monitors ignition timing, trial for ignition, system switches, flame sensing and lockout.

Carrier HK61EA002 fan control board with time delay relay. OEM replacement — cross-references 1171000. Fits Carrier, Bryant, and Payne air handlers.

Carrier HK61EA006 fan control board with integrated time delay relay. OEM replacement — cross-references 1171734. Fits Carrier, Bryant, and Payne air handlers.

Carrier HK61EA034 rectifier control board. Converts AC to DC for electronic components in Carrier, Bryant, and Payne air handlers. Replaces HK61EA004.

Carrier HK61EA020 defrost control board for heat pumps. Manages defrost cycles to prevent ice buildup. OEM Carrier/Bryant/Payne replacement.

Trane 57T01-843 time delay relay for air handlers. Keeps blower running 80 seconds after compressor shutdown. Replaces RLY02807, CNT05981. OEM Trane part.

York / Luxaire / Coleman (Source 1) OEM control board for X13 constant-torque motor applications.

York S1-031-03010-000 control board (50A56-956 aftermarket). Fits York single-stage gas furnaces. Replaces multiple 031-series York part numbers.

Rheem 47-100436-08 control board for Rheem and Ruud air handlers. OEM replacement with motor control and diagnostic capabilities.

Nordyne 1016380R control board. OEM replacement for Nordyne, Miller, and Intertherm air handlers. Replaces 624735-B. Controls blower motor and system functions.

Nordyne 903915A control board. OEM replacement for Nordyne gas furnaces. Also sold under part number 624643. Manages ignition, blower, and safety functions.

Honeywell S8610U3009 universal gas ignition control module (ICM2918). Replaces dozens of OEM ignition modules across Honeywell, Carrier, Goodman, and more.

Universal fan timer control board, replaces over 150 OEM models including Honeywell ST9120 series. Works with single-stage gas furnaces. Drop-in replacement for most brands.

Goodman PCBFM103S fan blower control board with time delay. Direct replacement for PCBFM131S and B1370735. Fits Goodman and Amana air handlers.

Goodman PCBBF145S control board. OEM replacement for Goodman and Amana furnaces including GMES960804CN. Manages ignition, blower, and safety functions.

Goodman PCBBF163S control board for GM9S series furnaces. OEM replacement. Also fits Daikin DM80SN models. Manages ignition, blower, and safety functions.

Lennox 16D74 time delay relay. 24 VAC input, 1-second delay on make, 45-second delay on break. OEM part for Lennox air handlers. Also listed as CT1S45.

Nordyne / Intertherm / Miller OEM control board. Nordyne publishes no public specification sheet for this part number, so voltages, amperages and application data are not stated here – verify against the board silkscreen before installing.

Trane CNT05482 defrost control board for heat pumps. Controls defrost cycle timing to prevent frost buildup on outdoor coil. OEM Trane part.

Carrier HK50AA051 terminal board (also listed as 1183618). Provides terminal connections for wiring inside commercial and residential Carrier/Bryant/Payne equipment.

Lennox 17W82 (LB-91097C) ignition control replacement kit. Replaces multiple older Lennox furnace boards including 21L890 and 72K79. Complete kit with harness.

Goodman PCBDM133S defrost control board for heat pumps. Replaces PCBDM160 and PCBDM161. Manages defrost timing on Goodman and Amana heat pumps.

ICM275C control board for Carrier furnaces. Replaces HH84AA001, HH84AA003, HH84AA005, HH84AA009, HH84AA014, HH84AA015, HH84AA021. Aftermarket direct fit.

Nortek 903106 gas furnace control board (ICM2805A aftermarket). Direct replacement for Nortek/Frigidaire furnaces. Manages ignition and blower operations.

ICM2812-KIT universal gas furnace control board kit. Replaces 200+ OEM boards including White-Rodgers 50M56U-843. Includes mounting hardware and wiring.

Rheem 62-105217-01 OEM control board for gas furnaces with spark ignition. Manages ignition, flame sensing, and blower operations in Rheem/Ruud systems.

Carrier HK61EA010 fan control board. OEM replacement for Carrier, Bryant, and Payne air handlers. Replaces part numbers HK61EA002 and HK61EA006. Also cross-references 1172975.

Ameristar BRD05765 control board. OEM replacement for Ameristar air handlers. Replaces BRD04300, BRD4300, and BRD5765. Controls blower and system functions.

Trane CNT05165 control board (50A65-5165 aftermarket). 80V HSI integrated furnace control for Trane and American Standard systems. Replaces CNT03076 and more.

York S1-03101264002 control board for electric furnaces in mobile homes. OEM replacement — also listed as S1-03101264003 and 334533. Controls fan and electric heat.

ICM291 direct spark ignition control board. Aftermarket replacement for Carrier LH33WP003. Used in Carrier rooftop units and furnaces to control the ignition sequence.

Goodman PCBDM101S defrost control board for heat pumps. Manages defrost cycles on Goodman and Amana heat pump systems. OEM replacement.

Rheem 47-102684-83 defrost control board kit with sensors. Manages defrost timing on Rheem/Ruud heat pumps. Includes defrost sensors.

Lennox direct spark ignition integrated control board, catalog number 21W14. The board manages the furnace ignition sequence and blower timing, driving the spark igniter and gas valve and monitoring flame.

Lennox 19W94 control board kit. OEM replacement for specific Lennox furnace models. Manages ignition, blower control, and system safety functions.

Trane CNT09648 OEM control board for A801X series furnaces. Replaces earlier CNT07940 revision. Full system management with LED diagnostic codes.

Rheem 62-24268-03 OEM control board for gas furnaces with hot surface ignition. Replaces 62-24268-01. Fits RGPJ series and similar Rheem/Ruud models.

Lennox 94W83 (103085-03) ignition control board. OEM replacement for single-stage Lennox furnaces with PSC blower motors. Direct factory fit.

Rheem 47-100436-84J blower control board for Rheem and Ruud air handlers. OEM replacement — also listed as 47-100436-04. Controls blower motor speed and airflow.

Defrost control board for Carrier, Bryant and Payne heat pumps, recorded internally as 1185790. The board times and terminates the defrost cycle, switching the reversing valve and cycling the outdoor fan based on the defrost thermostat and accumulated run time.

Carrier HK42FZ027 control board. OEM microprocessor-based board for Carrier, Bryant, and Payne furnaces. Manages ignition, blower, and system diagnostics.
The control board is the "brain" of your furnace or air handler. It manages the startup sequence, monitors safety switches, and controls blower speeds.
Power surges and lightning strikes are common causes of board failure in Dallas. A surge protector can prevent future damage.