0130F00036 – AUTO LIMIT SWITCH (MICRO, LARGE BASE, L180°)
Automatic-reset temperature limit switch for Goodman/Amana furnaces, recorded as a micro-style switch on a large base with an L180 degree F opening point.
Shop HVAC limit switches at Open To Public HVAC Parts in Dallas. We stock high-limit switches, auto-reset limit switches, rollout switches, and auxiliary limit controls for gas furnaces and air handlers. Compatible with Goodman, Rheem, Carrier, Trane, Lennox, and more.
Showing 1–48 of 83 results

Automatic-reset temperature limit switch for Goodman/Amana furnaces, recorded as a micro-style switch on a large base with an L180 degree F opening point.

Goodman/Amana 0130F00038S auto reset limit switch, opens at 120°F. Large base, micro size. Direct OEM replacement — also crosses to B13701-13 and L45-224.

York / Coleman / Luxaire auto-reset high limit switch with a 3 in. insertion probe, opening at 185°F on temperature rise and reclosing at 155°F.

Goodman 1370912S high limit switch with 7-inch insertion, opens at 240°F. OEM replacement for Goodman/Amana furnaces. Replaces older part 1370912.

Rheem 47-104990-04 high limit switch, 3-inch insertion, odd base, opens at 150°F. Auto reset. OEM replacement for Rheem and Ruud furnaces.

Rheem 47-22860-01 auto reset limit switch with built-in anticipator, opens at 105°F. OEM for Rheem and Ruud furnaces. Low-temp cutoff for heat pump applications.

Rheem 47-22860-02 auto reset limit switch with built-in anticipator, opens at 110°F. Replaces 47-22860-06. OEM for Rheem and Ruud furnaces.

Rheem 47-22861-03 manual reset limit switch, opens at 250°F. Wide mount, micro size. OEM flame rollout switch for Rheem and Ruud furnaces.

Rheem 47-25349-01 high limit switch, 3-inch insertion, odd base, opens at 160°F. Auto reset. Kit version (47-25349-01K). OEM for Rheem and Ruud furnaces.

Rheem 47-25349-03 high limit switch, 3-inch insertion, odd base, opens at 150°F. Auto reset. OEM replacement for Rheem and Ruud furnaces.

Honeywell L4064B2228 fan and limit control with 5-inch element. Adjustable fan differential and fixed high-limit safety cutoff. For older furnaces without electronic controls.

Honeywell L4064B2210 fan and limit control with 11-inch element. Adjustable fan differential and fixed high-limit safety cutoff. For older furnaces without electronic controls.

Honeywell L4064B2236 fan and limit control with 8-inch element. Adjustable fan differential and fixed high-limit safety cutoff. For older furnaces without electronic controls.

Flame rollout switch – a safety control that trips when flames roll out of the burner box, cutting the gas valve circuit.

Nordyne 626404R double-pole limit switch, opens at 145°F. Dual-stack design for Nordyne, Miller, and Intertherm furnaces. Also listed as 626404.

Nordyne 626458R double-pole limit switch, opens at 190°F. Dual-stack design for Nordyne, Miller, and Intertherm furnaces. Also listed as 626458.

Supco AT012 adjustable disc limit switch, 135°F to 175°F range. SPST open-on-rise. Crosses to E144 and PT012. Universal fit for furnaces and heating equipment.

Supco AT013 adjustable disc limit switch, 175°F to 215°F range. SPST open-on-rise. Crosses to Nordyne 626487R and PT013. Universal fit for furnaces.

Supco AT014 adjustable disc limit switch, 210°F to 250°F range. SPST open-on-rise. Crosses to PT014. Universal fit for furnaces and heating equipment.

Goodman B1370108 manual reset rollout limit switch, opens at 300°F. Large base, micro size. OEM safety switch for Goodman/Amana furnaces.

Goodman B1370110 manual reset rollout limit switch, opens at 330°F. Large base, micro size. OEM flame rollout safety switch for Goodman/Amana furnaces.

Goodman B1370115 heat kit limit switch, opens at 150°F. Protects electric heat strips in Goodman/Amana air handlers from overheating. OEM replacement part.

High-temperature limit switch for Goodman/Amana equipment, recorded as a disc-type switch with a deep back and an L120 degree F opening point.

High-temperature limit switch for Goodman/Amana furnaces, recorded as a 3 inch style with an L290 degree F opening point.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Carrier HH12ZB140 high limit switch, 3-inch insertion, opens at 140°F. Auto reset. Crosses to Supco SHL507, Trane SWT01276. Universal 3-inch L140 replacement.

Carrier HH12ZB150 high limit switch, 3-inch insertion, opens at 150°F. Auto reset. Crosses to Trane SWT01280. For Carrier, Bryant, Payne, and Trane furnaces.

Carrier HH12ZB160 high limit switch, 3-inch insertion, opens at 160°F. Auto reset. Crosses to Trane SWT01257. For Carrier, Bryant, Payne, and Trane furnaces.

High limit switch for Carrier, Bryant and Payne equipment, recorded as a 3 inch style rated L230 degrees F. It provides over-temperature protection by opening the control circuit when the sensing element reaches the set point.

Carrier HH12ZB260 high limit switch, 3-inch insertion, opens at 260°F. Auto reset. Crosses to Trane SWT01261. For Carrier, Trane, and other brand furnaces.

Carrier HH18HA148 auto reset limit switch, opens at 150°F. Large base, micro size. Crosses to 20162904S. OEM for Carrier, Bryant, and Payne systems.

Carrier HH18HA416 manual reset limit switch, opens at 215°F. Large base, micro size. OEM replacement for Carrier, Bryant, and Payne furnaces.

Carrier HH18HA449 manual reset limit switch, opens at 350°F. Large base, micro size. Used as a flame rollout switch on Carrier, Bryant, and Payne furnaces.

Carrier HH18HA452 manual reset rollout limit switch, opens at 250°F. Large base, micro size. OEM flame rollout switch for Carrier, Bryant, and Payne furnaces.

Carrier HH18HA461 manual reset limit switch, opens at 160°F. Large base, micro size. Also crosses to HH18HA167. OEM for Carrier, Bryant, and Payne systems.

Carrier HH18HA493 auto reset limit switch, opens at 200°F, closes at 101°F. Wide mount, micro size. Crosses to 1176902. OEM for Carrier, Bryant, and Payne.

Carrier HH18HA495 manual reset limit switch, opens at 350°F. Teardrop mount. Crosses to 1177033. OEM flame rollout switch for Carrier, Bryant, and Payne.

Temperature limit switch for Carrier, Bryant and Payne furnaces, recorded in our system as style MALB with a 200 degree F setting.

Carrier HH18HA499 auto reset limit switch, opens at 165°F, closes at 125°F. Large base, micro size. Crosses to HH18HA169, HH18HA508, 20162903. OEM Carrier part.

Automatic-reset limit switch for Carrier, Bryant and Payne furnaces, recorded as a large-base switch with an L220 degree F opening point.

Carrier HH18HA505 auto reset limit switch, opens at 235°F, closes at 195°F. OEM replacement for Carrier, Bryant, and Payne furnaces.
Limit switches are safety devices inside your furnace that monitor temperature. The high-limit switch shuts off burners if the heat exchanger gets too hot. The fan limit switch controls when the blower turns on and off.
Always check the air filter first. A clogged filter is the #1 reason a high-limit switch trips.