
HH12ZB230 – HIGH LIMIT SWITCH (3″, L230)
Shut off the breaker and the disconnect before a panel comes off. Then write down three things off the old switch before you buy - the L number, the probe length from the plate to the tip, and the mounting hole spacing. A limit that trips is almost always reporting an airflow problem, not causing one. Around Dallas we see it most in November, on furnaces that spent the whole long cooling season as an AC blower behind a filter nobody changed since May.
10226 Plano Rd, Suite 104, Dallas TX 75238
Questions? Call or text (214) 340-9421
Mon–Fri 10 am – 7 pm | Sat 10 am – 3 pm
High limit switch for Carrier, Bryant and Payne equipment, recorded as a 3 inch style rated L230 degrees F. It provides over-temperature protection by opening the control circuit when the sensing element reaches the set point. Both the 3 inch body style and the L230 rating must match the original for the switch to protect correctly. Carrier publishes no public part detail, so the specifications below come from our own stock records; confirm against the part nameplate before installing.
Specifications from our own stock records. The manufacturer does not publish a public page for this item.
Specs
- Part NumberHH12ZB230
- Brand (as recorded)Carrier
- Product TypeHigh limit switch
- Style3 inch
- Limit SettingL230 degrees F
- FunctionOpens control circuit on over-temperature
- Data SourceOTP stock record - not manufacturer-verified
Cross-reference numbers
This part replaces the following OEM and aftermarket numbers:
- 49L87
Not sure if your number matches? Call (214) 340-9421 or bring the old part in — bench-testing is free.
What does L200-40 mean on a furnace limit switch?
L is limit, 200 is the temperature in F where the contacts open on a rise, and 40 is the differential, so it closes back around 160F. That is an auto-reset disc. Manual-reset limits have a button and stay open until somebody pushes it. Bring the old one in so we can match the temperature, the mounting hole pattern, and the probe length together.
My limit keeps tripping. Is the switch bad?
Usually not. A limit is a safety reading real heat, and most repeat trips we hear about trace back to airflow - a loaded filter, closed or blocked registers, an undersized return, a dirty blower wheel, or a plugged evaporator coil sitting above the heat exchanger. Check temperature rise against the nameplate range, often 40-70F or 45-75F. Rise above the top number means airflow, not a bad switch.
Can I use a hotter limit if that is what is in stock?
No. L200, L230, L250 and L290 differ only by trip temperature and by base or probe size, and they are not interchangeable. Dropping a hotter limit into a furnace that specced a cooler one lets the heat exchanger run past the temperature it was tested to. That is defeating the safety, not fixing it.
Does insertion length matter?
Yes. A 3 inch probe where 5 inch was called for sits in the wrong part of the airstream, reads low, and trips late or never. Measure the old probe from the back of the mounting plate to the tip.




