SLS150 – AUTO LIMIT SWITCH (MICRO, L150°)
Supco SLS150 auto reset micro limit switch, opens at 150°F, closes at 110°F. Compact design with angled terminals. Universal fit for furnaces and unit heaters.
This is where you can browse products in this store.
Showing 1–48 of 83 results

Supco SLS150 auto reset micro limit switch, opens at 150°F, closes at 110°F. Compact design with angled terminals. Universal fit for furnaces and unit heaters.

Carrier HH18HA461 manual reset limit switch, opens at 160°F. Large base, micro size. Also crosses to HH18HA167. OEM for Carrier, Bryant, and Payne systems.

Manual reset micro rollout limit switch, opens at 300°F. Crosses to Goodman B1370145 and York S1-026-34027-000. Fits Goodman, Amana, and York furnaces.

Goodman B1370110 manual reset rollout limit switch, opens at 330°F. Large base, micro size. OEM flame rollout safety switch for Goodman/Amana furnaces.

Manual reset micro limit switch, opens at 130°F. Push-button reset after trip. Universal replacement for Supco SRL130 and Packard PRL130. Used in furnaces and heaters.

Supco SHL517 high limit switch, 3-inch insertion, opens at 220°F, closes at 180°F. Auto reset. Crosses to Carrier HH12ZB220 and Lennox 29M75.

Supco SHL513 high limit switch, 3-inch insertion, opens at 170°F, closes at 130°F. Auto reset. Crosses to Carrier HH12ZB170. Universal furnace fit.

Supco SHL522 high limit switch, 7-inch insertion, opens at 160°F, closes at 140°F. Auto reset. Crosses to Goodman B1370908/B13709-08. Direct Goodman replacement.

Honeywell L4064B2228 fan and limit control with 5-inch element. Adjustable fan differential and fixed high-limit safety cutoff. For older furnaces without electronic controls.

York S1-025-35362-000 auto reset limit switch, opens at 200°F, closes at 170°F. 3-inch insertion, odd base. OEM for York furnaces.

Carrier HH18HA507 auto reset limit switch, opens at 185°F, closes at 145°F. Large base, micro size. OEM replacement for Carrier, Bryant, and Payne furnaces.

Rheem 47-22860-02 auto reset limit switch with built-in anticipator, opens at 110°F. Replaces 47-22860-06. OEM for Rheem and Ruud furnaces.

Supco SLS140 auto reset micro limit switch, opens at 140°F, closes at 100°F. Compact design with angled terminals. Universal fit for furnaces and unit heaters.

Goodman/Amana 0130F00038S auto reset limit switch, opens at 120°F. Large base, micro size. Direct OEM replacement — also crosses to B13701-13 and L45-224.

High-temperature limit switch for Goodman/Amana equipment, recorded as a disc-type switch with a deep back and an L120 degree F opening point.

Supco SLS200 auto reset micro limit switch, opens at 200°F, closes at 160°F. Compact design with angled terminals. Universal fit for furnaces and unit heaters.

Manual reset micro limit switch, opens at 250°F. Push-button reset after trip. Replaces Supco SRL250 and Packard PRL250. Universal fit for furnaces and unit heaters.

Supco SHL516 high limit switch, 3-inch insertion, opens at 210°F, closes at 170°F. Auto reset. Crosses to Carrier HH12ZB210, Rheem 47-102473-04, and more.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Flame rollout switch – a safety control that trips when flames roll out of the burner box, cutting the gas valve circuit.

Supco SHL518 high limit switch, 3-inch insertion, opens at 250°F, closes at 210°F. Auto reset. Crosses to Carrier HH12ZB250. Universal furnace replacement.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Manual reset micro limit switch, opens at 220°F. Push-button reset after trip. Universal replacement — fits most furnaces and heaters using a micro-base L220 switch.

Manual reset micro limit switch, opens at 230°F. Push-button reset after trip. Universal replacement for Supco SRL230 and Packard PRL130. Fits most residential furnaces.

Manual reset micro limit switch, opens at 260°F. Push-button reset after trip. Replaces Supco SRL260 and Packard PRL260. Universal fit for residential furnaces.

Carrier HH18HA495 manual reset limit switch, opens at 350°F. Teardrop mount. Crosses to 1177033. OEM flame rollout switch for Carrier, Bryant, and Payne.

Rheem 47-104990-04 high limit switch, 3-inch insertion, odd base, opens at 150°F. Auto reset. OEM replacement for Rheem and Ruud furnaces.

Supco SHL508 high limit switch, 3-inch insertion, opens at 190°F, closes at 170°F. Auto reset. Crosses to Carrier HH12ZB190 and Trane SWT01259.

Supco SHL515 high limit switch, 3-inch insertion, opens at 200°F, closes at 160°F. Auto reset. Crosses to Carrier HH12ZB200. Universal furnace replacement.

Supco SLS160 auto reset micro limit switch, opens at 160°F, closes at 120°F. Compact design with angled terminals. Universal fit for furnaces and unit heaters.

Supco SLS300 auto reset rollout switch, opens at 300°F, closes at 250°F. Compact micro size with angled terminals. Used as a flame rollout safety switch.

Rheem 47-25349-03 high limit switch, 3-inch insertion, odd base, opens at 150°F. Auto reset. OEM replacement for Rheem and Ruud furnaces.

York / Coleman / Luxaire auto-reset high limit switch with a 3 in. insertion probe, opening at 185°F on temperature rise and reclosing at 155°F.

Automatic-reset temperature limit switch for Goodman/Amana furnaces, recorded as a micro-style switch on a large base with an L180 degree F opening point.

Furnace high-limit switch from the MAL series. A limit is a safety control: its normally closed contacts open to shut down the heating circuit when plenum temperature climbs past the set point.

Rheem 47-22861-03 manual reset limit switch, opens at 250°F. Wide mount, micro size. OEM flame rollout switch for Rheem and Ruud furnaces.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

High limit switch for Carrier, Bryant and Payne equipment, recorded as a 3 inch style rated L230 degrees F. It provides over-temperature protection by opening the control circuit when the sensing element reaches the set point.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Honeywell L4064B2236 fan and limit control with 8-inch element. Adjustable fan differential and fixed high-limit safety cutoff. For older furnaces without electronic controls.

Goodman B1370108 manual reset rollout limit switch, opens at 300°F. Large base, micro size. OEM safety switch for Goodman/Amana furnaces.

York / Coleman / Evcon OEM limit switch. Johnson Controls does not publish public specification sheets or cross-references for its York and Source 1 service parts, so no temperature rating, set point or amperage is listed here.

Honeywell L4064B2210 fan and limit control with 11-inch element. Adjustable fan differential and fixed high-limit safety cutoff. For older furnaces without electronic controls.

Carrier HH18HA505 auto reset limit switch, opens at 235°F, closes at 195°F. OEM replacement for Carrier, Bryant, and Payne furnaces.

Trane SWT02173 manual reset limit switch, opens at 310°F. Teardrop mount. Used as a flame rollout safety switch on Trane and American Standard furnaces.

Manual reset micro limit switch, opens at 240°F. Push-button reset after trip. Universal replacement for Supco SRL240 and Packard PRL240. Fits most furnaces and heaters.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.
Limit switches are safety devices inside your furnace that monitor temperature. The high-limit switch shuts off burners if the heat exchanger gets too hot. The fan limit switch controls when the blower turns on and off.
Always check the air filter first. A clogged filter is the #1 reason a high-limit switch trips.