UUV-CBM-PCO – ULTRAVIOLET LIGHT W/ PCO AIR CLEANER
Clear Blue PCO UV-C light with photocatalytic oxidation. 16-inch UV lamp plus PCO cell for advanced air cleaning. Kills mold and neutralizes odors and VOCs.
Walk in. We test every part free at the counter. Open to homeowners, contractors, and multifamily — no account or minimum order.
Popular: 45/5 capacitor ECM blower Honeywell ignitor 24V contactor Hard start kit

Ten departments, organized the way our counter is. Every category is on the shelf today.
Bring your old part. We'll diagnose it, find the replacement, and bench-test the new one at the counter before you leave — so you only make one trip.

¿Buscas partes de HVAC en Dallas?
Visita nuestra página en español — mismas partes, mismo mostrador, atendido en español.
Ver página en español →Showing 1–10 of 1617 results

Clear Blue PCO UV-C light with photocatalytic oxidation. 16-inch UV lamp plus PCO cell for advanced air cleaning. Kills mold and neutralizes odors and VOCs.

Goodman 15 kW electric heat kit with built-in circuit breaker. Adds supplemental or emergency heat to Goodman/Amana air handlers. Part #HKSC15XC.

Honeywell S8610U3009 universal gas ignition control module (ICM2918). Replaces dozens of OEM ignition modules across Honeywell, Carrier, Goodman, and more.

Goodman 0130F00508 dual furnace pressure switch, -0.55″ and -0.30″ WC. Two-stage switch for Goodman, Amana, and Janitrol furnaces with two-stage inducer motors.

14″ galvanized round duct coupling. Connects two pieces of flex duct together or joins flex duct to a metal collar. Standard slip-fit connection.

Milwaukee 48-32-4803 magnetic bit holder. 3-inch impact-duty design locks bits tight during high-torque driving. Fits all standard 1/4″ hex shank bits.

Nordyne 903915A control board. OEM replacement for Nordyne gas furnaces. Also sold under part number 624643. Manages ignition, blower, and safety functions.

Carrier HH12ZB160 high limit switch, 3-inch insertion, opens at 160°F. Auto reset. Crosses to Trane SWT01257. For Carrier, Bryant, Payne, and Trane furnaces.

Furnace high-limit switch from the MAL series. A limit is a safety control: its normally closed contacts open to shut down the heating circuit when plenum temperature climbs past the set point.

R-32 refrigerant in a 20 lb cylinder. R-32 is a lower-GWP A2L refrigerant used in newer equipment – EPA Section 608 certification and A2L-rated handling practices apply, and an A2L tank adaptor is needed to connect standard gauges.