15660 – REFRIGERANT HOSE (3/8″ HOSE, 5′ LONG)
$67.11Yellow Jacket 15660 heavy-duty 3/8″ charging and vacuum hose, 60″ (5 ft). 600 psi working pressure, 3000 psi burst. For larger systems and faster vacuum pulldown.
Shop HVAC refrigerants at Open To Public HVAC Parts in Dallas. We carry R-410A, R-22, R-407C, R-404A, and other specialty refrigerants for air conditioning and heat pump systems. Available in multiple cylinder sizes — stop by for same-day walk-in pickup. EPA certification required.
Showing all 35 results

Yellow Jacket 15660 heavy-duty 3/8″ charging and vacuum hose, 60″ (5 ft). 600 psi working pressure, 3000 psi burst. For larger systems and faster vacuum pulldown.

Yellow Jacket 19020 quick coupler gaskets for 1/4″, 5/16″, and 1/2″ Acme hose fittings. Replacement seals to stop hose leaks. Pack of gaskets.

Yellow Jacket 19041 SealRight 1/4″ complete overhaul kit. Rebuilds your low-loss quick couplers with new seals, springs, and o-rings. Cheaper than replacing the whole coupler.

Yellow Jacket 19109 SealRight 1/4″ straight low-loss fitting. Traps refrigerant automatically when you disconnect. Male flare, straight design.

Yellow Jacket 19209 SealRight 1/4″ 90-degree low-loss fitting. Traps refrigerant automatically when you disconnect. Male flare, elbow design for tight spaces.

Yellow Jacket 21012 PLUS II 12-inch recovery drier hose. 1/4″ with standard flare fittings. Short hose for connecting a filter drier inline during recovery.

Yellow Jacket 21985 PLUS II hose set — 3 pack, 60″ long, 1/4″ with standard flare fittings. Red, blue, and yellow. Double barrier construction for all refrigerants.

Yellow Jacket 22985 PLUS II hose set — 3 pack, 60″ long, 1/4″ with SealRight low-loss fittings. Red, blue, yellow. Traps refrigerant on disconnect.

Yellow Jacket 25985 PLUS II hose set — 3 pack, 60″ long, 1/4″ with FlexFlow ball valve fittings. Red, blue, yellow. Instant shutoff at the hose end.

Cliplight 301 valve core removal tool. Removes and installs Schrader valve cores without losing refrigerant charge. Seals the port while you work.

Yellow Jacket 42004 Series 41 manifold gauge set with 60″ PLUS II hoses. Brass body, 3-1/8″ gauges. Rated for R-404A, R-22, and R-410A.

Yellow Jacket 42036 Series 41 manifold gauge set with 60″ PLUS II hoses. Brass body, 3-1/8″ gauges. Rated for R-32, R-454B, and R-410A — ready for next-gen refrigerants.

Yellow Jacket 46010 BRUTE II 4-valve manifold — aluminum body, 3/8″ bore, no hoses. Full-size 3-1/8″ gauges. Faster vacuum and charging than 2-valve manifolds.

Yellow Jacket 49100 replacement gauge crystal, 3-1/8″ (80mm). Polycarbonate. Fits BRUTE II manifolds and other 3-1/8″ dry gauges. Clear view, impact resistant.

Yellow Jacket 49190 protective gauge boot set — red and blue rubber covers for 3-1/8″ manifold gauges. Cushion against drops and impacts without blocking the gauge face.

Yellow Jacket 93266 YJII vacuum pump — 5 CFM, 2-stage, 1/2 HP. Pulls down to 25 microns. Lightweight aluminum body. Workhorse pump for residential and light commercial HVAC.

Yellow Jacket 93843 compact ball valve adapter, 1/4″, 45-degree angle. Full flow for charging and recovery. Metal handle for durability.

CT-122 service ratchet wrench by Everwell. Four sizes in one chrome-plated tool with reversible ratchet. Built for HVAC valve and fitting work.

Mini-split adapter — 5/16″ female to 1/4″ male. Connects standard 1/4″ gauge hoses to R-410A mini-split service ports. Brass with quick coupler and depressor pin.

Fieldpiece DR82 infrared refrigerant leak detector. Detects leaks as small as 0.03 oz/yr. 10-year sensor life and 10-hour rechargeable battery. No false alarms from common gases.

ECBFF-1 ball valve for refrigerant hoses. 1/4″ connection, brass construction. Controls refrigerant flow during charging, recovery, and evacuation.

Fieldpiece JL3KH6 wireless charge and air test kit. Includes pressure probes, pipe clamps, and psychrometers for real-time HVAC diagnostics via Job Link app.

Fieldpiece JL3KR4 wireless refrigerant charge kit. Pressure probes and pipe clamps with 1000-foot wireless range and Rapid Rail sensors for fast superheat/subcooling readings.

DiversiTech MG-1 brass manifold gauge set with 60″ hoses. Works with R-22, R-410A, and R-407C. Good starter set for DIY or light commercial work.

Fieldpiece MG44 wireless vacuum micron gauge. A2L compatible, 1000-foot wireless range. Rugged design with reversible angled coupler for tight access during evacuations.

Fieldpiece MR45 refrigerant recovery machine. 1 HP DC motor, A2L compatible, self-purge function, three auto-stop levels. Fast, efficient recovery for all common refrigerants.

DiversiTech RC-1 liquid charging adapter. Converts liquid refrigerant to vapor before it enters the compressor. Protects the compressor during charging.

Everwell RCPT-31 can piercing tool. Taps into R-12, R-22, and R-134a refrigerant cans. Screw-on design with valve for controlled flow.

Supco SF3813 valve core tool with 3 replacement cores. 3-inch all-brass body with textured grip. Removes and installs Schrader valve cores on AC service ports.

Fieldpiece SM382V digital refrigerant manifold. A2L compatible, wireless Job Link connectivity, built-in vacuum gauge. Reads pressure, temperature, superheat, and subcooling.

Fieldpiece SM480V 4-port digital refrigerant manifold. A2L compatible, wireless connectivity, integrated vacuum gauge. The 4-port upgrade for more complex refrigerant work.

Fieldpiece SR47 wireless refrigerant scale. 252 lb capacity with remote control. Connects to Job Link app for wireless monitoring during charging and recovery.

Fieldpiece SRS1 wired refrigerant scale. 110 lb capacity with weight alarms for charging and recovery. Water-resistant, portable, and built for field use.

Fieldpiece TC24 pipe clamp thermocouple. Fits 3/8″ to 1-3/8″ pipes for accurate line temperature readings. Essential for superheat and subcooling measurements on AC systems.

Fieldpiece VP67 vacuum pump, 6 CFM, 2-stage, A2L compatible. RunQuick oil change system for fast maintenance. Built for fast, deep evacuations on AC installations.