SWT01714 – DOOR INTERLOCK SWITCH (TRANE, CARRIER, YORK)
Universal door interlock switch (SWT01714). Fits Trane, Carrier, York, and more. SPST, 125/250VAC, 21A rated. Shuts off the furnace when the access panel is removed.
Walk in. We test every part free at the counter. Open to homeowners, contractors, and multifamily — no account or minimum order.
Popular: 45/5 capacitor ECM blower Honeywell ignitor 24V contactor Hard start kit

Ten departments, organized the way our counter is. Every category is on the shelf today.
Bring your old part. We'll diagnose it, find the replacement, and bench-test the new one at the counter before you leave — so you only make one trip.

¿Buscas partes de HVAC en Dallas?
Visita nuestra página en español — mismas partes, mismo mostrador, atendido en español.
Ver página en español →Showing 401–410 of 1617 results

Universal door interlock switch (SWT01714). Fits Trane, Carrier, York, and more. SPST, 125/250VAC, 21A rated. Shuts off the furnace when the access panel is removed.

10″ x 8″ clockwise blower wheel with convex blades and 1/2″ bore. OEM Goodman part. Also replaces Morrison BW43016 and Carrier LA22LA014/LA22LA015.

12″ galvanized start collar for connecting round duct to a sheet metal or ductboard plenum. Crimped end for easy duct attachment. Standard residential HVAC ductwork fitting.

Lennox / Allied Air ECB45-series electric heat section, 15 kW at 208/240V single phase, 60 Hz, with factory-installed circuit breaker protection (one 60 A and one 25 A breaker). Lennox lists it for CBK45 and CBA25 series air handlers.

Supco low-pressure switch — opens at 20 PSI, closes at 45 PSI. 1/4″ SAE flare fitting, auto-reset. Protects compressor from low refrigerant pressure.

TurboTorch TDLX2010B torch kit for brazing and soldering. Works with 40 cu ft acetylene tanks. Includes regulator, hose, handle, and tip for larger jobs.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.

45+10 MFD 440V dual run capacitor. Powers both the compressor and condenser fan motor. Budget-friendly TrueLine replacement for residential AC.

24V SPST heat sequencer. OEM Rheem/Ruud part for electric furnaces. Single-pole single-throw configuration for staging one heating element.

25 MFD 440V round run capacitor. Powers a single motor — compressor or fan. American-made by Titan HD with 60,000-hour rated life.