42-23116-01 – HEAT SEQUENCER (SPST)
24V SPST heat sequencer. OEM Rheem/Ruud part for electric furnaces. Single-pole single-throw configuration for staging one heating element.
Walk in. We test every part free at the counter. Open to homeowners, contractors, and multifamily — no account or minimum order.
Popular: 45/5 capacitor ECM blower Honeywell ignitor 24V contactor Hard start kit

Ten departments, organized the way our counter is. Every category is on the shelf today.
Bring your old part. We'll diagnose it, find the replacement, and bench-test the new one at the counter before you leave — so you only make one trip.

¿Buscas partes de HVAC en Dallas?
Visita nuestra página en español — mismas partes, mismo mostrador, atendido en español.
Ver página en español →Showing 1441–1450 of 1617 results

24V SPST heat sequencer. OEM Rheem/Ruud part for electric furnaces. Single-pole single-throw configuration for staging one heating element.

Goodman PCBBF145S control board. OEM replacement for Goodman and Amana furnaces including GMES960804CN. Manages ignition, blower, and safety functions.

Hydro-Balance Neutronic H-NT08 odor neutralizer gel, 8 oz. Compact size for smaller spaces. Eliminates HVAC odors at the source instead of masking them.

Victor G150-15-200R acetylene regulator. Compact single-stage design for light-duty brazing and soldering. CGA200 connection fits standard acetylene tanks.

Air-proving (draft) pressure switch used on Goodman/Amana gas furnaces. It senses negative pressure produced by the inducer blower and closes to allow the ignition sequence to proceed, keeping the burner from firing if venting is blocked or the inducer is not moving air.

Supco FCN waterless condensate trap — replaces traditional P-traps. No water to dry out, freeze, or clog with sludge. Compact design for tight spaces.

45+7.5 MFD 440V dual run capacitor. Powers both the compressor and condenser fan motor. Fits most residential AC systems. American-made by Titan HD.

10″ x 25′ insulated flex duct (R8 fiberglass insulation). Standard residential HVAC flexible ductwork for supply air runs. Quietflex brand.

Snap-disc furnace high-limit switch from the DL series; the number is the opening (cut-out) temperature in degrees F. It is a safety device that breaks the heating circuit when the plenum overheats, and a limit that keeps tripping points at restricted airflow or a failed blower rather than at the switch.