1/2C90 – REFRIGERATION COPPER FITTING (1/2″ 90° ELBOW, LONG RADIUS)
1/2″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.
Shop HVAC copper tubing and fittings at Open To Public HVAC Parts in Dallas. We carry copper line sets, soft and hard refrigeration tubing, sweat fittings, and copper connectors for air conditioning and refrigeration installations. Cut to length available — stop by for same-day pickup.
Showing all 34 results

1/2″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

1/2″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

1/2″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 1/2″ copper pipe in a straight line. Wrot copper for brazing.

1/2″ x 50′ soft copper refrigeration tubing. ACR (air conditioning/refrigeration) grade — clean, dehydrated, and capped. Use for suction lines and liquid lines.

1/4 in. refrigeration copper 90 degree elbow, long radius, cup x cup. The long-radius sweep turns a refrigerant line 90 degrees with less flow restriction than a short-radius elbow.

1/4 in. refrigeration copper coupling with an internal stop, cup x cup. Solders two lengths of same-size ACR copper tube together; the stop centers the fitting so each tube bottoms evenly in the socket.

1/4″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Commonly used for liquid lines in residential AC systems.

1-1/8″ to 7/8″ ACR copper reducer bushing (FTG x C). Steps down from 1-1/8″ fitting to 7/8″ copper pipe. Wrot copper for brazing.

3/4 in. refrigeration copper 45 degree elbow, long radius, cup x cup. Used for 45 degree offsets on larger suction lines where a gentle turn is preferred over a hard 90. Sized by tube OD, the standard convention for ACR fittings.

3/4″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

3/4″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

3/4″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 3/4″ copper pipe in a straight line. Wrot copper for brazing.

Silver brazing rings, 3/4 in., for making brazed copper refrigerant joints. The part number indicates 25 per pack.

3/4″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Common suction line size for residential AC systems up to 3 tons.

3/8 in. refrigeration copper 45 degree elbow, long radius, cup x cup. Makes a 45 degree offset in a refrigerant line – typical on 3/8 in. liquid or small suction lines routing around framing.

3/8″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

3/8″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

3/8″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 3/8″ copper pipe in a straight line. Wrot copper for brazing.

Silver brazing rings, 3/8 in., for making brazed copper refrigerant joints. The part number indicates 25 per pack.

3/8″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Common liquid line size for residential AC systems.

5/8″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

5/8″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

5/8″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 5/8″ copper pipe in a straight line. Wrot copper for brazing.

5/8″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Common suction line size for smaller residential AC and mini-splits.

7/8 in. refrigeration copper 45 degree elbow, long radius, cup x cup. Handles 45 degree offsets on large suction lines in commercial and higher-tonnage residential systems.

7/8″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

7/8″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

7/8″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 7/8″ copper pipe in a straight line. Wrot copper for brazing.

Silver brazing rings, 7/8 in., for making brazed copper refrigerant joints. The part number indicates 25 per pack.

7/8″ x 3/4″ ACR copper reducer coupling (C x C). Connects 7/8″ and 3/4″ copper pipe directly. Wrot copper for brazing.

7/8″ x 3/4″ ACR copper reducer bushing (FTG x C). Steps down from 7/8″ fitting to 3/4″ copper pipe. Wrot copper for brazing.

7/8″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Standard suction line for 3-5 ton residential AC systems.

Mini-split line set — 25 ft, 1/4″ liquid x 1/2″ suction, pre-flared ends. Insulated suction line. Ready to install on most 9,000-12,000 BTU ductless systems.

Mini-split line set — 25 ft, 1/4″ liquid x 3/8″ suction, pre-flared ends. Insulated suction line. Fits most 9,000 BTU ductless systems.