7/8X3/4CRED – COPPER FITTING (REDUCER BUSHING, FTGxC)
7/8″ x 3/4″ ACR copper reducer bushing (FTG x C). Steps down from 7/8″ fitting to 3/4″ copper pipe. Wrot copper for brazing.
This is where you can browse products in this store.
Showing all 26 results

7/8″ x 3/4″ ACR copper reducer bushing (FTG x C). Steps down from 7/8″ fitting to 3/4″ copper pipe. Wrot copper for brazing.

1/2″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

5/8″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

1/2″ x 50′ soft copper refrigeration tubing. ACR (air conditioning/refrigeration) grade — clean, dehydrated, and capped. Use for suction lines and liquid lines.

1/2″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

5/8″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

3/8″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

3/8″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

3/4″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 3/4″ copper pipe in a straight line. Wrot copper for brazing.

7/8″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

5/8″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Common suction line size for smaller residential AC and mini-splits.

7/8″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 7/8″ copper pipe in a straight line. Wrot copper for brazing.

3/4″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

Mini-split line set — 25 ft, 1/4″ liquid x 1/2″ suction, pre-flared ends. Insulated suction line. Ready to install on most 9,000-12,000 BTU ductless systems.

Mini-split line set — 25 ft, 1/4″ liquid x 3/8″ suction, pre-flared ends. Insulated suction line. Fits most 9,000 BTU ductless systems.

3/8″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Common liquid line size for residential AC systems.

1/2″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 1/2″ copper pipe in a straight line. Wrot copper for brazing.

3/8″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 3/8″ copper pipe in a straight line. Wrot copper for brazing.

7/8″ ACR copper 90° long radius elbow (C x C). Wrot copper for brazing. Changes direction of refrigerant lines without restricting flow.

3/4″ ACR copper 90° long radius street elbow (FTG x C). One end fits inside a fitting, the other accepts pipe. Wrot copper for brazing.

5/8″ ACR copper coupling with rolled stop (C x C). Joins two pieces of 5/8″ copper pipe in a straight line. Wrot copper for brazing.

3/4″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Common suction line size for residential AC systems up to 3 tons.

1/4″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Commonly used for liquid lines in residential AC systems.

7/8″ x 50′ soft copper refrigeration tubing. ACR grade — clean, dehydrated, and capped. Standard suction line for 3-5 ton residential AC systems.

1-1/8″ to 7/8″ ACR copper reducer bushing (FTG x C). Steps down from 1-1/8″ fitting to 7/8″ copper pipe. Wrot copper for brazing.

7/8″ x 3/4″ ACR copper reducer coupling (C x C). Connects 7/8″ and 3/4″ copper pipe directly. Wrot copper for brazing.