0130F00504 – FURNACE PRESSURE SWITCH (-0.60PF)
$37.04Goodman 0130F00504 furnace pressure switch, -0.60″ WC. OEM replacement for Goodman and Amana furnaces. Also cross-references B1370142.
Shop furnace pressure switches at Open To Public HVAC Parts in Dallas. We carry draft pressure switches, vent pressure switches, and blocked vent safety switches for gas furnaces. Compatible with Goodman, Rheem, Carrier, Trane, Lennox, and more — OEM and aftermarket options in stock.
Showing all 17 results

Goodman 0130F00504 furnace pressure switch, -0.60″ WC. OEM replacement for Goodman and Amana furnaces. Also cross-references B1370142.

Goodman 0130F00505 furnace pressure switch, -0.70″ WC. Fits Goodman GMS80905CN series and others. Also replaces B1370158, 10727923, and 632432R.

Goodman 0130F00508 dual furnace pressure switch, -0.55″ and -0.30″ WC. Two-stage switch for Goodman, Amana, and Janitrol furnaces with two-stage inducer motors.

Nordyne 1010775R furnace pressure switch, -0.20″ WC, two hose ports. Fits Nordyne, Intertherm, and Miller furnaces. Also listed as 632453.

Rheem 42-101225-81 furnace pressure switch, -0.35″ WC. OEM replacement for Rheem and Ruud gas furnaces. Monitors inducer draft for safe ignition.

Rheem 42-101233-81 furnace pressure switch, -0.35″ WC. OEM for Rheem/Ruud RGPJ series furnaces. Also replaces 42-24194-01 and 42-24194-01K.

Rheem 42-105583-04 furnace pressure switch, -0.40″ WC. OEM replacement for Rheem and Ruud gas furnaces. Verifies inducer draft before ignition.

Rheem 42-105601-29 furnace pressure switch, -0.20″ WC. OEM Rheem part that also cross-references to Carrier HK06WC090. Works in both Rheem and Carrier furnaces.

Rheem 42-24194-82 furnace pressure switch, -0.30″ WC. OEM for Rheem and Ruud furnaces. Also listed as 42-106257-01. Monitors inducer draft for safe operation.

Goodman B1370126 furnace pressure switch, -0.40″ WC. OEM replacement for Goodman furnaces. Also replaces 20055506 and R102614-01.

Goodman B1370133 furnace pressure switch, -0.35″ WC. OEM replacement for Goodman gas furnaces. Monitors inducer draft for safe ignition.

Goodman B1370176 furnace pressure switch, -0.47″ WC. OEM replacement for Goodman gas furnaces. Verifies proper inducer draft before ignition.

Carrier HK06WC069 furnace pressure switch, -0.27″ WC. OEM for Carrier, Bryant, and Payne furnaces. Replaces 1176957 and HK06WC091. Also listed as NS2-1600-00.

York S1-02435271000 furnace pressure switch, -0.50″ WC. OEM for York, Coleman, and Luxaire furnaces. Replaces 024-27576-000, 49L91, and C341750P01.

York S1-32435972000 furnace pressure switch, -0.10″ WC. OEM replacement for York, Coleman, and Luxaire furnaces. Also replaces 024-27666-000 and NS2-1604-00.

Supco SSRT3165 red silicone pressure switch tubing, 1/4″ ID x 60″. Handles -100°F to 500°F. Replaces cracked or melted rubber tubing on furnace inducer pressure switches.

Trane SWT04232 dual furnace pressure switch, -0.17″ and -0.50″ WC. For two-stage Trane/American Standard furnaces. Also replaces SWT02357 and C340789P02.
The pressure switch is a safety device that confirms the inducer motor is pulling proper draft before allowing gas to flow. If it fails or can't close, the furnace won't ignite.
Before replacing the pressure switch, check: (1) Is the drain line clogged? (2) Is the inducer hose cracked? (3) Is the flue vent blocked? These are the most common causes.