0130M00138S – TRANSFORMER (240V, 40VA, PF40224)
$35.86Goodman 0130M00138S transformer, 208/240V to 24V, 40VA. Steps down line voltage for the control circuit. Direct OEM replacement for Goodman/Amana air handlers and furnaces.
Showing all 4 results

Goodman 0130M00138S transformer, 208/240V to 24V, 40VA. Steps down line voltage for the control circuit. Direct OEM replacement for Goodman/Amana air handlers and furnaces.

Goodman 0130M00140S transformer, 120V to 24V, 40VA. Steps down line voltage to 24V for the thermostat and control circuit. Direct OEM replacement for Goodman/Amana.

Multi-tap transformer, 120/208/240V to 24V, 40VA. Universal foot-mount design fits most residential and light commercial HVAC systems. Replaces Jard 4031OEM and Mars 44517.

Multi-voltage step-down transformer, 120/208/240/480V to 24V, 100VA with built-in circuit breaker. Heavy-duty for systems that need more than 40VA. Foot mount.
The transformer steps down your home's 120V or 240V power to the 24V that operates the thermostat, control board, and gas valve. When it fails, the low-voltage control circuit goes dead.
If the fuse keeps blowing after replacement, there's likely a short in the thermostat wiring. Don't just keep replacing fuses — find the short.