1P32A24V – CONTACTOR (SCREW TERMINALS)
$30.70Rheem 42-109499-24 single-pole 32A contactor with 24V coil and screw terminals. OEM replacement for Rheem and Ruud AC condensers.
Showing all 48 results

Rheem 42-109499-24 single-pole 32A contactor with 24V coil and screw terminals. OEM replacement for Rheem and Ruud AC condensers.

Rheem 42-105601-29 furnace pressure switch, -0.20″ WC. OEM Rheem part that also cross-references to Carrier HK06WC090. Works in both Rheem and Carrier furnaces.

Rheem 42-107430-03 circuit breaker, 60A, 2-pole, 230V, DIN rail mount, lug/lug connections. Provides overcurrent protection inside the HVAC equipment cabinet.

Rheem 42-22692-06 furnace door safety switch. SPST normally open, push-button style. Shuts off the furnace when the access panel is removed. Also fits York.

Rheem 42-23114-06 fan relay. 24V SPDT. OEM replacement for Rheem and Ruud furnaces and air handlers. Controls blower fan on/off switching.

24V TPST heat sequencer. OEM Rheem/Ruud part for electric furnaces. Triple-pole single-throw for staging three circuits on timed delay.

24V TPST heat sequencer. OEM Rheem/Ruud part for electric furnaces. Triple-pole single-throw for staging three circuits. Different timing than 42-23116-07.

Rheem 42-24194-82 furnace pressure switch, -0.30″ WC. OEM for Rheem and Ruud furnaces. Also listed as 42-106257-01. Monitors inducer draft for safe operation.

Rheem 425097 circuit breaker, 60A, 2-pole, DIN rail mount, lug-to-quick-connect terminals. Internal equipment breaker for Rheem/Ruud heat pumps and air handlers.

Copeland compressor wiring harness, 10 AWG, 6-foot lead. Molded plug connects to the compressor terminals. Rheem OEM part 45-100834-80.

LG compressor wiring harness. Molded plug connects to the compressor terminals. Rheem OEM part 45-107231-02. Also cross-references 104162-03 and 13U63.

Rheem 47-100436-02 control board for air handlers with X13 ECM motors. OEM replacement — also cross-references 47-102077-02, 47-102077-05, and 48X21-811.

Rheem 47-100436-05 control board for air handlers with PSC motors. OEM replacement for Rheem and Ruud air handlers. Manages blower motor speed and timing.

Rheem 47-102684-204 defrost control board for heat pumps. Manages defrost timing to prevent ice buildup on outdoor coil. OEM Rheem/Ruud replacement.

Rheem 47-102684-83 defrost control board kit with sensors. Manages defrost timing on Rheem/Ruud heat pumps. Includes defrost sensors.

Rheem 47-104990-04 high limit switch, 3-inch insertion, odd base, opens at 150°F. Auto reset. OEM replacement for Rheem and Ruud furnaces.

Rheem 47-22860-01 auto reset limit switch with built-in anticipator, opens at 105°F. OEM for Rheem and Ruud furnaces. Low-temp cutoff for heat pump applications.

Rheem 47-22861-03 manual reset limit switch, opens at 250°F. Wide mount, micro size. OEM flame rollout switch for Rheem and Ruud furnaces.

Rheem 47-25349-01 high limit switch, 3-inch insertion, odd base, opens at 160°F. Auto reset. Kit version (47-25349-01K). OEM for Rheem and Ruud furnaces.

Rheem 62-105217-01 OEM control board for gas furnaces with spark ignition. Manages ignition, flame sensing, and blower operations in Rheem/Ruud systems.

Rheem 62-23543-01 flame sensor replacement. Fits Rheem and Ruud furnace models including RGPH and UGPH series. Aftermarket direct fit, listed as FLS301.

Rheem OEM direct spark ignitor with round pin connector. Part 62-24164-01. For Rheem/Ruud furnaces with spark ignition (not hot surface).

Rheem OEM direct spark ignitor with 5/16″ quick connect. Part 62-24164-03. For Rheem/Ruud furnaces with spark ignition (not hot surface).

Rheem 62-25338-01 OEM control board for gas furnaces with direct spark ignition. Manages ignition, flame sensing, and blower operations in Rheem/Ruud systems.

Aftermarket inducer motor assembly for Rheem/Ruud furnaces. 115V, 3000 RPM. Replaces 70-101087-81 and 70-24175-01. Complete assembly with motor, housing, and wheel.

10-5/8″ x 10-3/4″ clockwise blower wheel with concave blades and 1/2″ bore. OEM Rheem part. Also replaces Goodman B1368047S and Carrier LA22ZA123.

11″ x 10″ clockwise blower wheel with concave blades and 1/2″ bore. Rheem 70-20602-01 cross-reference. Also replaces Goodman B1368000S and Carrier S1-02634501000.

Aftermarket inducer motor for Rheem/Ruud furnaces. 120V, 3000 RPM, 1/30 HP. Replaces 70-24157-03. Right-side discharge. Complete assembly.

Rheem AE-61698-82 screw shell motor mount kit, 4-arm. OEM replacement for 48-frame blower motors in Rheem and Ruud furnaces and air handlers.

Rheem R801T0503A14UHSNAS gas furnace, 50,000 BTU, 80% AFUE, 14″ cabinet. Constant torque ECM blower motor with PlusOne diagnostics. Upflow/horizontal install. SEER2 compliant.

Rheem R801T0754A17UHSNAS gas furnace, 75,000 BTU, 80% AFUE, 17″ cabinet. Constant torque ECM blower motor with PlusOne diagnostics. Upflow/horizontal install. SEER2 compliant.

Rheem R801T0754A21UHSNAS gas furnace, 75,000 BTU, 80% AFUE, 21″ cabinet. Constant torque ECM blower motor with PlusOne diagnostics. Upflow/horizontal install. SEER2 compliant.

Rheem R801T1005A21UHSNAS gas furnace, 100,000 BTU, 80% AFUE, 21″ cabinet. Constant torque ECM blower motor with PlusOne diagnostics. Upflow/horizontal install. SEER2 compliant.

Rheem RA14AZ18AJ1NA 1.5-ton AC condenser. 14.3 SEER2, R-410A, single-stage scroll compressor. Pre-charged refrigerant. 10-year registered warranty.

Rheem RCFZ6021STAAMC evaporator coil, 5-ton, R-410A, 21″ cabinet width. Cased coil for upflow/downflow applications. SEER2 compliant.

Rheem RH1PZ2417STANNJ 2-ton air handler. 17″ width, R-410A compatible, PSC motor, SEER2 compliant. Pairs with Rheem RA14AZ24 condenser for a complete system.

Rheem RH1PZ3617STANNJ 3-ton air handler. 17″ width, R-410A compatible, PSC motor, SEER2 compliant. Pairs with Rheem RA14AZ36 condenser for a complete system.

Rheem RH2TZ3617STANNJ 3-ton air handler with Constant Torque ECM motor. 17″ width, R-410A, SEER2 compliant. More efficient and quieter than PSC models.

Rheem RP14AZ24AJ2NA heat pump condenser, 2-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.

Rheem RP14AZ30AJ2NA heat pump condenser, 2.5-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.

Rheem RP14AZ36AJ2NA heat pump condenser, 3-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.

Rheem RP14AZ42AJ2NA heat pump condenser, 3.5-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.

Rheem RP14AZ48AJ2NA heat pump condenser, 4-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.

Rheem RP14AZ60AJ2NA heat pump condenser, 5-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.

Rheem 10 kW electric heat kit for SEER2 air handlers. Part #RXBH-1724A10J-BR. Includes circuit breaker, smart plug, and legacy board adapter.

Rheem 15 kW electric heat kit for SEER2 air handlers. Part #RXBH-1724A15J-BR. Includes circuit breaker, smart plug, and legacy board adapter.

Rheem 20 kW electric heat kit for SEER2 air handlers. Part #RXBH-24A20J-BR. Includes built-in circuit breaker and nickel-chromium elements.

Rheem RH2TZ6024STANNJ 5-ton air handler. Constant Torque ECM motor, R-410A compatible, SEER2 compliant. 24″ wide cabinet with multiple installation options.