Symptoms of failure
- AC hums but the fan and compressor will not start
- Outdoor fan only starts if you push it with a stick
- Compressor tries to start, clicks, then trips the breaker
- System short-cycles or runs warm on a hot afternoon
- The capacitor top is domed, split, or leaking oil
- Unit worked this morning and quit in the heat of the day
Seeing these does not always mean this part is the culprit. Bring the old one in and we will meter it at the counter, free, before you buy.
If your AC won’t start, hums but doesn’t kick on, or runs but won’t cool, a bad capacitor is the most common cause. The Turbo 200 Mini adjusts from 2.5 to 15 MFD — replaces small fan motor caps. Dial to the MFD you need when you can’t find the exact oval cap for your fan motor.
Specs: 2.5-15 MFD adjustable, 370/440V, compact (MARS 12100)
Replaces: TURBO200MINI, MARS 12100, any single run cap 2.5-15 MFD
Fits: Residential and light commercial fan motor applications. All major brands.
Need help? See our AC Not Cooling Troubleshooting Guide or Capacitor Cross-Reference Chart.
In stock at Open To Public HVAC Parts in Dallas. We test parts at the counter before you buy. Call or text (214) 340-9421.
Specs
- TypeCapacitor
- Detail2.5 to 15 MFD
Installing it yourself
- Kill power at the disconnect and confirm 0V. A capacitor stores a lethal charge with the power off.
- Discharge it: bridge the terminals with an insulated-handle screwdriver, or a 20k ohm resistor, then confirm 0V with a meter.
- Photograph the wiring before you pull a single wire. HERM, FAN and C are not interchangeable.
- Loosen the mounting strap and lift the old capacitor out.
- Match MFD exactly. Voltage may go up (370V to 440V) but never down.
- Land the wires on the same terminals, strap it down, restore power.
- Never handle a swollen or leaking capacitor by the terminals - bring it in and we will dispose of it.
Power off at the disconnect first, every time. Not sure partway through? Bring it to the counter and we will walk it with you.
Cross-reference numbers
This part replaces the following OEM and aftermarket numbers:
- 12100
- AMRAD12100
Not sure if your number matches? Call (214) 340-9421 or bring the old part in — bench-testing is free.
Do I need an account to buy from you?
No. No account, no appointment, no minimums, and no contractor licence required. We have been open to the public in Dallas since 1998.
Do you ship?
No. Everything is sold in person at the counter - 10226 Plano Rd, Suite 104, Dallas TX 75238.
Can you help me work out what I need?
That is what the counter is for. Bring the old part, or a photo of the data plate, and we will work through it with you.
Do you test parts?
We meter capacitors, contactors, motors, ignitors, relays and transformers free at the counter, whether or not you buy from us.
What are your hours?
Monday to Friday 10am to 7pm, Saturday 10am to 3pm.