☀️ AC Season Is Here — Capacitors, Contactors & Motors In Stock. Browse Parts or Call (214) 340-9421
📞 (214) 340-9421 | Mon–Fri 10–7 • Sat 10–3 | ⭐ 4.9 (546 reviews) | ¿Hablas español? | Get Directions
TUTCO

KFFEH3301C20A – HEAT KIT (20 KW, 81-24741-00, R454)

SKU KFFEH3301C20A·Replaces 81-24741-00, EHC20BKB1, EHC20BKB
$500.59
In-store price · paid at counter
Low Stock at our Dallas counter
Tested before you leave. Free at the counter.
In-Store Only — We Don’t Ship
Every part is sold in person at our Dallas counter. No shipping, no online orders. Solo venta en tienda — no hacemos envíos.
Visit our Dallas counter to purchase
10226 Plano Rd, Suite 104 · Dallas TX 75238
Open now · Closes 7pm·Mon–Fri 10am–7pm · Sat 10am–3pm
Free part testingBench-tested at the counter
27,000+ in stockToday, on the shelf
4.9 · 546 reviewson Google
Since 199828 years on Plano Rd
Pro tip

ICP / Carrier / Heil / Tempstar HKTSD and HKSC heat kits fit ICP-platform air handlers. Match kW to tonnage: 10 kW for 1.5 / 2 / 2.5 ton; 15 kW for 3 / 3.5 / 4 ton; 20 kW for 5 ton. Match the part number suffix carefully -- different suffixes indicate different breaker / circuit configurations even at the same kW rating. Disconnect main power before installing; some HKTSD kits have factory pigtail wiring that connects to specific pin colors on the air handler control board.

Free Part Testing
27,000+ In Stock
4.9 Stars · 546+ Reviews
Since 1998
🏪 In-Store Pickup Only — We do not offer shipping or online ordering. Visit our Dallas location to purchase.
In Stock

Visit our Dallas store to purchase

Call (214) 340-9421Get Directions
In Stock — Pick Up at Our Dallas Store

10226 Plano Rd, Suite 104, Dallas TX 75238

Questions? Call or text (214) 340-9421

Mon–Fri 10 am – 7 pm  |  Sat 10 am – 3 pm

Carrier/Bryant KFFEH accessory electric heater package, 20 kW at 240V, 230V single phase, with an internal circuit breaker. Carrier’s KFFEH instructions cover installation in FJ4 and PF4MNX fan coils – the current fan coil platform – for fan coil sizes 30-60. The older KFCEH kits are the equivalents for the previous fan coil generation.

Specifications published by the manufacturer. Source: manufacturer documentation.

Specs

  • BrandTUTCO
  • Heating Capacity20 kW @ 240 V
  • Heating Capacity @ 230 V62,800 BTU/h
  • Voltage / Phase230 V / 1 Ph
  • Stages (kW operating)5 kW and 20 kW
  • Internal ProtectionCircuit breaker
  • Fits Fan CoilsCarrier/Bryant FJ4, PF4MNX
  • Fan Coil Sizes30-60
  • Heater Amps (208 / 240 V)71.2 / 78.8 A single point; 35.6 / 39.4 A and 35.6 / 39.4 A dual
  • Minimum Ampacity96.6 / 106.1 A single point; 52.1 / 56.9 A and 44.5 / 49.3 A dual
  • Max Fuse or Breaker100 / 110 A single point; 60 / 60 A and 45 / 50 A dual