HUNG-RITE – EQUIPMENT HANGER – 66″
Weigh the job before you buy the hanger. The rating you need covers the unit plus a wet coil plus a full secondary pan, and the ends have to land on a truss or joist, never on decking. While you are up there, put a float switch in that auxiliary pan even if nothing requires it on paper. In a 140F Dallas attic the drain is going to grow algae eventually, and a five dollar switch is what keeps that off the ceiling.
10226 Plano Rd, Suite 104, Dallas TX 75238
Questions? Call or text (214) 340-9421
Mon–Fri 10 am – 7 pm | Sat 10 am – 3 pm
Hung-Rite HVAC equipment hanger, 66 in., for suspending air handlers and other equipment. The manufacturer describes it as using adjustable cables for quick installation, but publishes no load rating we could cite.
Specs
- BrandHung-Rite
- Length66 in.
- TypeHVAC equipment hanger
- Load ratingNot published - verify before use
- Data SourceOTP stock record - not manufacturer-verified
Cross-reference numbers
This part replaces the following OEM and aftermarket numbers:
- HRHGR66-W10
- HRHGR66-WO
- Y7897
Not sure if your number matches? Call (214) 340-9421 or bring the old part in — bench-testing is free.
What does an equipment hanger have to hold?
The wet weight of the unit, not the shipping weight. An air handler full of a wet coil, plus a secondary drain pan and the water in it, is meaningfully heavier than the number on the carton. Read the hanger's rated capacity and stay under it, and land the ends on structure - a truss or joist - not on decking or a single piece of sheathing.
Do I still need a drain pan if the unit is hung?
Yes. Hanging an air handler does not remove the requirement for an auxiliary pan and a secondary drain or a float switch under equipment installed above a finished space. Hanging it just means the pan hangs with it. In a Dallas attic that pan plus a float switch is the difference between a service call and a ceiling.
Why hang an air handler instead of setting it on a platform?
Two reasons. It gets the cabinet off the attic deck so a leak is visible and drainable instead of soaking into insulation, and it lets you pitch the unit properly toward the drain. It also makes the filter rack reachable, which is the part people regret when it is buried on a platform in the far corner.
Does it matter which way the strap runs?
Yes. Support the cabinet under its structural rails, keep the unit level side to side and pitched only as the manufacturer's instructions call for, and do not let a strap bear on the drain pan lip or the access panels. A cabinet that is racked will not seal its panels, and an air handler that pulls attic air is one of the cheapest efficiency losses there is.