F100F1625/U – FILTER RACK (16″ x 25″)
Measure the cabinet width before you buy - the base has to match the equipment, and the filter size follows from that, not the other way round. And check whether the base takes 1" only or 1"/2"/4"; a deep media filter needs a base built for the depth.
10226 Plano Rd, Suite 104, Dallas TX 75238
Questions? Call or text (214) 340-9421
Mon–Fri 10 am – 7 pm | Sat 10 am – 3 pm
The Honeywell F100 media air cleaner is a whole-house filtration upgrade that mounts at your furnace or air handler. It uses thick MERV 11 media filters that capture dust, pollen, pet dander, and particles down to 0.3 microns — much better than a standard 1-inch filter. Change the media once or twice a year.
Specs: 16×25 filter size, MERV 11, 1,400 CFM, 0.3 micron capture
Replaces: F100F1625, F100F1625U
Fits: Air handlers and furnaces using 16×25 filter openings. Compatible with Carrier, Goodman, Rheem, Trane, Lennox, and others.
In stock at Open To Public HVAC Parts in Dallas. We test parts at the counter before you buy. Call or text (214) 340-9421.
Specs
- TypeFilter rack
- Cabinet size16"W x 25"D
- Filter size16" x 25"
- PositionReturn side, upstream of the blower and coil
Cross-reference numbers
This part replaces the following OEM and aftermarket numbers:
- F100F1625
- F100F1625U
- HONEYWELLF100F
Not sure if your number matches? Call (214) 340-9421 or bring the old part in — bench-testing is free.
What size filter base do I need?
It is sized to the furnace or air handler cabinet it bolts to, and to the filter that goes in it. A 20"W x 25"D base takes a 20x25 filter. Measure the cabinet width first - the base has to match the equipment, and the filter follows from that.
Can I put a 4 inch filter in it?
Only if the base is built for it. Some of our bases accept 1", 2" or 4" media; others are 1" only. Check the listing - a 4 inch filter will not go into a 1 inch rack no matter how you angle it.
What is the difference between a filter base and a filter rack?
A filter base is a sheet metal section that sits under the furnace and forms part of the cabinet, with the filter slot built in. A filter rack is a frame that mounts on the return side to hold a filter. Both do the same job in different places.
Why go to a 4 inch media filter?
Far more filter surface area, so it catches more while restricting airflow less, and it lasts six to twelve months instead of one to three. It needs the deeper slot, which is the whole reason to change the base.
Does the filter go in before or after the blower?
On the return side, before the blower and before the coil. That is the point of it - everything downstream stays clean.
Do you stock these?
We keep common sizes on the shelf at 10226 Plano Rd, Suite 104 in Dallas. Bring the furnace model and the cabinet width.