25X22X36R6 – PLENUM
Measure the equipment opening first and the clearance second - a plenum that fits the furnace but not the closet is the most expensive way to learn the attic is tight. In an unconditioned space use insulated board; an uninsulated plenum in a Dallas attic will sweat and stain a ceiling.
10226 Plano Rd, Suite 104, Dallas TX 75238
Questions? Call or text (214) 340-9421
Mon–Fri 10 am – 7 pm | Sat 10 am – 3 pm
A plenum is the sheet metal box that connects your air handler or cased coil to the ductwork in your home. If you’re replacing an air handler or adding ductwork, you’ll need one that matches your unit’s opening size. This one measures 25″ x 22″ at the opening and is 36″ long.
Specs: 25″ x 22″ opening, 36″ length, R6 fiberglass insulation, galvanized steel
Replaces: Universal — fits any air handler or coil with a 25″ x 22″ opening
Fits: Air handlers and cased evaporator coils with a matching 25″ x 22″ opening from Goodman, Rheem, Trane, Carrier, Lennox, and others
In stock at Open To Public HVAC Parts in Dallas. We test parts at the counter before you buy. Call or text (214) 340-9421.
Specs
- TypeSheet metal plenum
- Dimensions25"W x 22"D x 36"H
- InsulationR6 insulated board
Cross-reference numbers
This part replaces the following OEM and aftermarket numbers:
- 08726222536
- 25X22X36R6
Not sure if your number matches? Call (214) 340-9421 or bring the old part in — bench-testing is free.
What size plenum do I need?
It has to match the equipment it bolts to and the space it lives in. The three numbers are width, depth and height in inches. Measure the furnace or air handler opening first, then the clearance you have.
What does R6 mean?
The R-value of the insulation. R6 is the common insulated plenum board rating - the higher the number, the more it resists heat transfer. Insulation on a plenum matters most in an attic or garage where the surrounding air is nowhere near room temperature.
Supply or return plenum?
The supply plenum sits on the discharge side and feeds the trunk lines. The return plenum is on the intake side, usually with the filter in or near it. They are built the same way but sized to different openings.
Why is my plenum sweating?
Warm humid air hitting a cold metal surface. That is what the insulation is for - an uninsulated or poorly sealed plenum in a Dallas attic will drip and eventually stain the ceiling below.
Do you cut these to size?
We stock common sizes on the shelf. Bring the equipment model and your measurements to 10226 Plano Rd, Suite 104 in Dallas and we will work out what fits.