1P32A24V – CONTACTOR (SCREW TERMINALS)
Rheem 42-109499-24 single-pole 32A contactor with 24V coil and screw terminals. OEM replacement for Rheem and Ruud AC condensers.
Showing 1–48 of 54 results

Rheem 42-109499-24 single-pole 32A contactor with 24V coil and screw terminals. OEM replacement for Rheem and Ruud AC condensers.

Rheem 42-105601-29 furnace pressure switch, -0.20″ WC. OEM Rheem part that also cross-references to Carrier HK06WC090. Works in both Rheem and Carrier furnaces.

Rheem 42-107430-03 circuit breaker, 60A, 2-pole, 230V, DIN rail mount, lug/lug connections. Provides overcurrent protection inside the HVAC equipment cabinet.

Rheem 42-22692-06 furnace door safety switch. SPST normally open, push-button style. Shuts off the furnace when the access panel is removed. Also fits York.

Rheem 42-23114-06 fan relay. 24V SPDT. OEM replacement for Rheem and Ruud furnaces and air handlers. Controls blower fan on/off switching.

24V TPST heat sequencer. OEM Rheem/Ruud part for electric furnaces. Triple-pole single-throw for staging three circuits on timed delay.

24V TPST heat sequencer. OEM Rheem/Ruud part for electric furnaces. Triple-pole single-throw for staging three circuits. Different timing than 42-23116-07.

Rheem 42-24194-82 furnace pressure switch, -0.30″ WC. OEM for Rheem and Ruud furnaces. Also listed as 42-106257-01. Monitors inducer draft for safe operation.

Rheem 425097 circuit breaker, 60A, 2-pole, DIN rail mount, lug-to-quick-connect terminals. Internal equipment breaker for Rheem/Ruud heat pumps and air handlers.

Copeland compressor wiring harness, 10 AWG, 6-foot lead. Molded plug connects to the compressor terminals. Rheem OEM part 45-100834-80.

Bristol/Danfoss compressor wiring harness. Molded plug connects to the compressor terminals. Rheem OEM part 45-102303-01.

LG compressor wiring harness. Molded plug connects to the compressor terminals. Rheem OEM part 45-107231-02. Also cross-references 104162-03 and 13U63.

Rheem 47-100436-02 control board for air handlers with X13 ECM motors. OEM replacement — also cross-references 47-102077-02, 47-102077-05, and 48X21-811.

Rheem 47-100436-05 control board for air handlers with PSC motors. OEM replacement for Rheem and Ruud air handlers. Manages blower motor speed and timing.

Rheem 47-102684-204 defrost control board for heat pumps. Manages defrost timing to prevent ice buildup on outdoor coil. OEM Rheem/Ruud replacement.

Rheem 47-102684-83 defrost control board kit with sensors. Manages defrost timing on Rheem/Ruud heat pumps. Includes defrost sensors.

Rheem 47-104990-04 high limit switch, 3-inch insertion, odd base, opens at 150°F. Auto reset. OEM replacement for Rheem and Ruud furnaces.

Rheem 47-22860-01 auto reset limit switch with built-in anticipator, opens at 105°F. OEM for Rheem and Ruud furnaces. Low-temp cutoff for heat pump applications.

Rheem 47-22861-03 manual reset limit switch, opens at 250°F. Wide mount, micro size. OEM flame rollout switch for Rheem and Ruud furnaces.

Rheem 47-25349-01 high limit switch, 3-inch insertion, odd base, opens at 160°F. Auto reset. Kit version (47-25349-01K). OEM for Rheem and Ruud furnaces.

Rheem 62-104058-02 OEM control board for gas furnaces with spark ignition. Also listed as 1194-200. Manages ignition, flame sensing, and blower operations.

Rheem 62-105217-01 OEM control board for gas furnaces with spark ignition. Manages ignition, flame sensing, and blower operations in Rheem/Ruud systems.

Rheem 62-23543-01 flame sensor replacement. Fits Rheem and Ruud furnace models including RGPH and UGPH series. Aftermarket direct fit, listed as FLS301.

Rheem 62-24140-04 OEM control board for gas furnaces with direct spark ignition. Replaces 62-24140-02. ICM292 is the aftermarket equivalent. Fits RGPH/UGPH models.

Rheem OEM direct spark ignitor with round pin connector. Part 62-24164-01. For Rheem/Ruud furnaces with spark ignition (not hot surface).

Rheem OEM direct spark ignitor with 5/16″ quick connect. Part 62-24164-03. For Rheem/Ruud furnaces with spark ignition (not hot surface).

Rheem 62-25338-01 OEM control board for gas furnaces with direct spark ignition. Manages ignition, flame sensing, and blower operations in Rheem/Ruud systems.

Aftermarket inducer motor assembly for Rheem/Ruud furnaces. 115V, 3000 RPM. Replaces 70-101087-81 and 70-24175-01. Complete assembly with motor, housing, and wheel.

Rheem 70-102011-22 condenser fan blade — 18″, 2-blade, 27° pitch, CCW rotation, hub on intake side. OEM replacement for Rheem and Ruud outdoor units.

10-5/8″ x 10-3/4″ clockwise blower wheel with concave blades and 1/2″ bore. OEM Rheem part. Also replaces Goodman B1368047S and Carrier LA22ZA123.

11″ x 10″ clockwise blower wheel with concave blades and 1/2″ bore. Rheem 70-20602-01 cross-reference. Also replaces Goodman B1368000S and Carrier S1-02634501000.

Aftermarket inducer motor for Rheem/Ruud furnaces. 120V, 3000 RPM, 1/30 HP. Replaces 70-24157-03. Right-side discharge. Complete assembly.

11″ x 9″ clockwise blower wheel with convex blades. Sold as Rheem 703016. Fits multiple Rheem and Carrier/Bryant air handlers.

Rheem AE-58384-81 screw shell motor mount kit, 4-arm. OEM replacement for mounting 48-frame blower motors in Rheem and Ruud furnaces and air handlers.

Rheem AE-61698-82 screw shell motor mount kit, 4-arm. OEM replacement for 48-frame blower motors in Rheem and Ruud furnaces and air handlers.

Rheem R801T0503A14UHSNAS gas furnace, 50,000 BTU, 80% AFUE, 14″ cabinet. Constant torque ECM blower motor with PlusOne diagnostics. Upflow/horizontal install. SEER2 compliant.

Rheem R801T0754A17UHSNAS gas furnace, 75,000 BTU, 80% AFUE, 17″ cabinet. Constant torque ECM blower motor with PlusOne diagnostics. Upflow/horizontal install. SEER2 compliant.

Rheem R801T0754A21UHSNAS gas furnace, 75,000 BTU, 80% AFUE, 21″ cabinet. Constant torque ECM blower motor with PlusOne diagnostics. Upflow/horizontal install. SEER2 compliant.

Rheem R801T1005A21UHSNAS gas furnace, 100,000 BTU, 80% AFUE, 21″ cabinet. Constant torque ECM blower motor with PlusOne diagnostics. Upflow/horizontal install. SEER2 compliant.

Rheem RA14AZ18AJ1NA 1.5-ton AC condenser. 14.3 SEER2, R-410A, single-stage scroll compressor. Pre-charged refrigerant. 10-year registered warranty.

Rheem RCFZ6021STAAMC evaporator coil, 5-ton, R-410A, 21″ cabinet width. Cased coil for upflow/downflow applications. SEER2 compliant.

Rheem RH1PZ2417STANNJ 2-ton air handler. 17″ width, R-410A compatible, PSC motor, SEER2 compliant. Pairs with Rheem RA14AZ24 condenser for a complete system.

Rheem RH1PZ3617STANNJ 3-ton air handler. 17″ width, R-410A compatible, PSC motor, SEER2 compliant. Pairs with Rheem RA14AZ36 condenser for a complete system.

Rheem RH2TZ3617STANNJ 3-ton air handler with Constant Torque ECM motor. 17″ width, R-410A, SEER2 compliant. More efficient and quieter than PSC models.

Rheem RP14AZ24AJ2NA heat pump condenser, 2-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.

Rheem RP14AZ30AJ2NA heat pump condenser, 2.5-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.

Rheem RP14AZ36AJ2NA heat pump condenser, 3-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.

Rheem RP14AZ42AJ2NA heat pump condenser, 3.5-ton, R-410A, 14.3 SEER2, two-stage scroll compressor. Swept Wing fan for quiet operation. 10-year registered warranty.