42-23114-06 – RELAY (24 VAC COIL)
Rheem 42-23114-06 fan relay. 24V SPDT. OEM replacement for Rheem and Ruud furnaces and air handlers. Controls blower fan on/off switching.
Showing all 31 results

Rheem 42-23114-06 fan relay. 24V SPDT. OEM replacement for Rheem and Ruud furnaces and air handlers. Controls blower fan on/off switching.

Trane 57T01-843 time delay relay for air handlers. Keeps blower running 80 seconds after compressor shutdown. Replaces RLY02807, CNT05981. OEM Trane part.

Goodman B1370738 fan switching relay/sequencer (Q108 aftermarket). 24V SPDT. Controls the blower fan timing in Goodman and Amana furnaces.

Lennox 16D74 time delay relay. 24 VAC input, 1-second delay on make, 45-second delay on break. OEM part for Lennox air handlers. Also listed as CT1S45.

24V DPST relay with 30-amp capacity. OEM Carrier/Bryant/Payne part HN61PC003. Replaces older HN61PC002 and cross-reference T92S7D22-24.

Carrier HN61PC005 fan relay (1178205). 24V DPST, 30A capacity. OEM replacement for Carrier and Bryant furnaces and air handlers.

22V DC SPST relay for electric heaters in ICP/Heil/Tempstar units. Rated 30A at 28V DC and 40A at 277V AC. Direct replacement for ICP furnaces.

24V SPST fan relay (90380). Controls the indoor blower fan on/off. Quick-connect terminals, universal mounting. One of the most common HVAC relay types.

24V SPDT fan relay (90370). Controls the indoor blower fan. Quick-connect terminals with multi-position mounting. Universal replacement for many furnaces.

24V DPDT fan relay (90340). Controls the indoor blower fan in heating and cooling modes. Quick-connect terminals, multi-position mounting. Universal replacement.

TD73 time delay relay, delay-on-break. Adjustable 6 seconds to 5 minutes, 19-250 VAC/VDC. Keeps the fan running after the compressor shuts off to extract residual cooling.

TD69 time delay relay, delay-on-make. Adjustable 6 seconds to 8 minutes, 19-250 VAC/VDC. Prevents compressor short cycling by delaying startup after a call for cooling.

Supco SPP8E E-Series hard start kit for 1-5 ton compressors. Electronic relay covers the widest tonnage range. The go-to universal hard start.

Supco SPP6E E-Series hard start kit for 1-3 ton compressors. Electronic relay — more precise and reliable than mechanical kits. Easy 3-wire install.

Supco SPP10E E-Series hard start kit for 3.5-5 ton compressors. Electronic relay built for larger systems. More reliable than mechanical relay kits.

Supco MAG1YL magnetic jumper wire, 20 inches. Magnetic tips clip to terminals for hands-free HVAC diagnostics. Rated 30 VAC/VDC, 5 amps. Yellow wire.

Supco FC4031 universal fan center. Built-in 40VA transformer (120/208/240V to 24V) plus DPDT relay in one unit. Replaces separate transformer and relay combos.

Supco 3W3 hard start kit for 4-5 ton compressors. 3-wire design with potential relay and start capacitor. Heavy-duty option for the largest residential systems.

Supco 3W2 hard start kit for 3.5-5 ton compressors. 3-wire design with potential relay and start capacitor. Built for larger residential and light commercial AC.

Supco 3W1 hard start kit for 1-3 ton compressors. 3-wire design with potential relay and start capacitor. Gets stubborn compressors running on hot days.

Carrier/Bryant/Payne rectifier board. Converts AC to DC for relay control in electric heat systems. OEM part HK61EA033, replaces older HK61EA003.

Carrier HK61EA002 fan control board with time delay relay. OEM replacement — cross-references 1171000. Fits Carrier, Bryant, and Payne air handlers.

Carrier HK61EA006 fan control board with integrated time delay relay. OEM replacement — cross-references 1171734. Fits Carrier, Bryant, and Payne air handlers.

Lennox 619559-01 defrost control board kit (16V37) for heat pumps. Time/temperature defrost with anti-short-cycle protection. OEM Lennox.

Lennox 16V38 defrost control board for heat pumps. Time/temperature defrost control with anti-short-cycle protection. OEM Lennox replacement.

24V triple-stacked heat sequencer for Lennox electric furnaces. Thermal time delay relay that stages heating elements and fan activation.

Goodman PCBFM103S fan blower control board with time delay. Direct replacement for PCBFM131S and B1370735. Fits Goodman and Amana air handlers.

24V heat sequencer with two DPDT relays in series. Handles up to 25 amps. Replaces HS24A346. For electric furnaces with multi-stage heating elements.

24V heat sequencer with 1 DPST and 1 SPST relay in series. Handles up to 25 amps. Replaces Nordyne 621678 and HS24A345. Common electric furnace part.

Jumper cord with alligator clips on one end and a female socket on the other. Used for temporary power during HVAC and electrical diagnostics. For professional use.