W51-MHCJA1-02 – CONDENSER MOTOR (1/3 – 1/4 – 1/5 HP, 1075 RPM, 10 MFD)
$142.691/3 to 1/5 HP condenser fan motor, 1075 RPM, 208-230V, 10 MFD cap. Multi-HP replacement for Goodman, Trane, Carrier, Lennox, and more.
Showing 1–48 of 250 results

1/3 to 1/5 HP condenser fan motor, 1075 RPM, 208-230V, 10 MFD cap. Multi-HP replacement for Goodman, Trane, Carrier, Lennox, and more.

1/2 to 1/3 HP ECM X13 constant-torque blower motor, dual voltage 115/208-230V. Fits Goodman, Trane, Lennox, and more. Preprogrammed with installation harness.

3/4 to 1/5 HP furnace blower motor, 115V, 1075 RPM, multi-speed reversible. Requires 15 MFD capacitor. Fits Trane, Carrier, and other 115V furnaces.

3/4 HP air handler blower motor, 208-230V, 1075 RPM, 3-speed reversible. Requires 15 MFD capacitor. Replaces Lennox 19L40 and WG840590.

3/4 HP ECM X13 constant-torque blower motor, 115/208-230V dual voltage. Replaces multiple Goodman, Trane, and Lennox X13 motors. Preprogrammed with harness.

1/6 HP 1075 RPM condenser fan motor, 208-230V, 10 MFD cap required. Direct replacement for WG840727. Fits multiple residential condenser brands.

1/4 HP 825 RPM condenser fan motor, 208-230V, 48Y frame, 5 MFD cap. Direct OEM replacement for Goodman, Lennox, and other brands.

1/4 HP air handler blower motor, 208-230V, 1075 RPM, 3-speed reversible. Requires 10 MFD capacitor. The 230V version for air handlers that need a 1/4 HP motor.

1/4 HP furnace blower motor, 120V, 1075 RPM, 3-speed reversible. Requires 10 MFD capacitor. Budget-friendly option for smaller furnaces and air handlers.

1/3 HP air handler blower motor, 208-230V, 3-speed, reversible rotation. Requires 10 MFD capacitor. Replaces Lennox 19L36 and multiple GE/Genteq motors.

1/3 HP furnace blower motor, 120V, 1075 RPM, 3-speed reversible. Requires 10 MFD capacitor. Fits Goodman, Trane, Lennox, Carrier, and other 115V furnaces.

1/2 HP air handler blower motor, 208-230V, 3-speed, reversible rotation. Requires 10 MFD capacitor. Replaces Lennox 19L38 and D801205P01.

1 HP ECM X13 constant-torque blower motor, 115/208-230V dual voltage. Replaces multiple Goodman, Trane, and Lennox X13 motors. Preprogrammed with harness included.

Aftermarket inducer motor assembly for Carrier furnaces. Two-speed, thermally protected. Replaces 326628-761 and multiple cross-references. Complete assembly by Packard (66761).

Rheem AE-61698-82 screw shell motor mount kit, 4-arm. OEM replacement for 48-frame blower motors in Rheem and Ruud furnaces and air handlers.

Rheem AE-58384-81 screw shell motor mount kit, 4-arm. OEM replacement for mounting 48-frame blower motors in Rheem and Ruud furnaces and air handlers.

Rheem 47-100436-05 control board for air handlers with PSC motors. OEM replacement for Rheem and Ruud air handlers. Manages blower motor speed and timing.

York OEM 1 HP double-shaft blower motor. 115V, 1100 RPM, 4-speed. Direct fit for York furnaces and air handlers. Replaces F48E34A48 and S83-536.

Honeywell M847D-ZONE zone damper motor/actuator. 24VAC, spring-return. Fits ARD, EARD, and ZD series zone dampers. Direct-couples to 7/16″ damper shaft.

Goodman B1376857 motor mount arms, set of 3. OEM replacement for Goodman and Amana furnaces and air handlers. Secures the blower motor in the housing.

Goodman B1376851 motor belly band. Wraps around the blower motor to hold it in place inside the blower housing. OEM Goodman/Amana part.

Motor module adapter — converts 16-pin connector to 4-pin for Genteq Evergreen VS or model 3.0 ECM motors. Required when replacing a GE 2.5 ECM with a newer Evergreen.

Carrier OEM inducer motor gasket kit. Seals the inducer motor housing to prevent exhaust gas leaks. Use when replacing the inducer motor or if you smell exhaust fumes near the furnace.

Supco ECMPRO universal ECM motor tester. 24 VAC powered with 24-inch leads, magnetic case, and short circuit protection. Tests most ECM blower motors without the furnace board.

Aftermarket inducer motor for Carrier furnaces. 115V, 1/25 HP, 3300 RPM. Replaces 318984-753, HC21ZE114, HC21ZE117, and HC21ZE123. Fits a wide range of Carrier models.

Aftermarket inducer motor assembly for York furnaces. 115V, 1/25 HP, 3000 RPM, CCW rotation. Replaces S1-02435329000. Complete Fasco A228 assembly.

1/3-1/6 HP 2-speed condenser motor, 825 RPM, 208-230V. Trane mounting configuration. Replaces Trane and other brand condenser fan motors.

3/4 HP air handler blower motor, 208-230V, 1075 RPM, 4-speed reversible. Requires 10 MFD 370V capacitor (sold separately). The 230V version of the EM3466.

3/4 HP furnace blower motor, 115V, 1075 RPM, 4-speed reversible. Requires 10 MFD 370V capacitor (sold separately). Direct replacement for US Motors 55470.

Fasco D338 double-shaft blower motor. 1/6 HP, 4-speed, 1550 RPM, 115V. 4.4-inch diameter with resilient ring mount and auto overload protection. Fits fan coils and PTACs.

Fasco D337 double-shaft blower motor. 1/8 HP, 4-speed, 1550 RPM, 115V. 4.4-inch diameter with resilient ring mount. Fits wall heaters, fan coils, and small units.

Fasco D258 double-shaft blower motor. 1/5 to 1/10 HP, 1550 RPM, 208-230V. 5-inch diameter with resilient ring mount, sleeve bearings, and auto overload protection.

1/2″ to 5/8″ motor shaft bushing. Adapts a 1/2″ motor shaft to fit a 5/8″ bore blower wheel or pulley. Steel with keyway slot.

Aftermarket inducer motor assembly for Trane/American Standard furnaces. 115V, 3000 RPM, 1/50 HP. Replaces BLW00889. Complete assembly with motor, wheel, housing, and gaskets.

Aftermarket inducer motor for Goodman furnaces. 115V, 3000 RPM, 1/40 HP. Replaces B1859005. Complete assembly with motor, wheel, housing, and gasket.

Aftermarket inducer motor for Lennox furnaces. 120V, 3000 RPM, 1/60 HP. Replaces 85L49. Complete assembly with motor, wheel, housing, and gaskets.

Aftermarket inducer motor for Rheem/Ruud furnaces. 120V, 3000 RPM, 1/30 HP. Replaces 70-24157-03. Right-side discharge. Complete assembly.

1-1/3 HP universal ECM blower motor by U.S. Motors. 115/230V dual voltage, 1075 RPM. Replaces 16-pin variable speed models including EON and Nidec ECMs.

Aftermarket inducer motor assembly for ICP/Heil/Tempstar furnaces. 115V, 1.6A. Replaces 1013833. Complete assembly with motor, housing, and wheel.