W51-MHBDV-04 – BLOWER MOTOR – ECM X13 – CONSTANT TORQUE (1/2-1/3 HP, DUAL VOLTAGE)
1/2 to 1/3 HP ECM X13 constant-torque blower motor, dual voltage 115/208-230V. Fits Goodman, Trane, Lennox, and more. Preprogrammed with installation harness.
Showing 1–48 of 85 results

1/2 to 1/3 HP ECM X13 constant-torque blower motor, dual voltage 115/208-230V. Fits Goodman, Trane, Lennox, and more. Preprogrammed with installation harness.

3/4 to 1/5 HP furnace blower motor, 115V, 1075 RPM, multi-speed reversible. Requires 15 MFD capacitor. Fits Trane, Carrier, and other 115V furnaces.

3/4 HP air handler blower motor, 208-230V, 1075 RPM, 3-speed reversible. Requires 15 MFD capacitor. Replaces Lennox 19L40 and WG840590.

3/4 HP ECM X13 constant-torque blower motor, 115/208-230V dual voltage. Replaces multiple Goodman, Trane, and Lennox X13 motors. Preprogrammed with harness.

1/4 HP air handler blower motor, 208-230V, 1075 RPM, 3-speed reversible. Requires 10 MFD capacitor. The 230V version for air handlers that need a 1/4 HP motor.

1/4 HP furnace blower motor, 120V, 1075 RPM, 3-speed reversible. Requires 10 MFD capacitor. Budget-friendly option for smaller furnaces and air handlers.

1/3 HP air handler blower motor, 208-230V, 3-speed, reversible rotation. Requires 10 MFD capacitor. Replaces Lennox 19L36 and multiple GE/Genteq motors.

1/3 HP furnace blower motor, 120V, 1075 RPM, 3-speed reversible. Requires 10 MFD capacitor. Fits Goodman, Trane, Lennox, Carrier, and other 115V furnaces.

1/2 HP air handler blower motor, 208-230V, 3-speed, reversible rotation. Requires 10 MFD capacitor. Replaces Lennox 19L38 and D801205P01.

1 HP ECM X13 constant-torque blower motor, 115/208-230V dual voltage. Replaces multiple Goodman, Trane, and Lennox X13 motors. Preprogrammed with harness included.

York OEM 1 HP double-shaft blower motor. 115V, 1100 RPM, 4-speed. Direct fit for York furnaces and air handlers. Replaces F48E34A48 and S83-536.

3/4 HP air handler blower motor, 208-230V, 1075 RPM, 4-speed reversible. Requires 10 MFD 370V capacitor (sold separately). The 230V version of the EM3466.

3/4 HP furnace blower motor, 115V, 1075 RPM, 4-speed reversible. Requires 10 MFD 370V capacitor (sold separately). Direct replacement for US Motors 55470.

Fasco D338 double-shaft blower motor. 1/6 HP, 4-speed, 1550 RPM, 115V. 4.4-inch diameter with resilient ring mount and auto overload protection. Fits fan coils and PTACs.

Fasco D337 double-shaft blower motor. 1/8 HP, 4-speed, 1550 RPM, 115V. 4.4-inch diameter with resilient ring mount. Fits wall heaters, fan coils, and small units.

Fasco D258 double-shaft blower motor. 1/5 to 1/10 HP, 1550 RPM, 208-230V. 5-inch diameter with resilient ring mount, sleeve bearings, and auto overload protection.

1-1/3 HP universal ECM blower motor by U.S. Motors. 115/230V dual voltage, 1075 RPM. Replaces 16-pin variable speed models including EON and Nidec ECMs.

Nortek 622686 ECM blower motor — 1/2 HP, 1050 RPM, 208-230V, 48-frame. Variable speed with proprietary PWM harness. Direct replacement for 622686R.

1/2 to 1/6 HP air handler blower motor, 208-230V, 1075 RPM with reversible rotation. Requires 10 MFD capacitor. Thermal overload protection built in.

1/2 HP furnace blower motor, 115V, 1075 RPM, 4-speed with 10 MFD capacitor required. Replaces WG840463 and multiple Goodman/Trane furnace motors. Reversible rotation.

1/4 HP double-shaft blower motor. 1625 RPM, 208-230V with PSC technology and auto overload protection. Direct fit for First Company M10 air handlers and similar units.

Aftermarket inducer motor assembly for Carrier furnaces. Two-speed, thermally protected. Replaces 326628-761 and multiple cross-references. Complete assembly by Packard (66761).

Rheem AE-61698-82 screw shell motor mount kit, 4-arm. OEM replacement for 48-frame blower motors in Rheem and Ruud furnaces and air handlers.

Rheem AE-58384-81 screw shell motor mount kit, 4-arm. OEM replacement for mounting 48-frame blower motors in Rheem and Ruud furnaces and air handlers.

Rheem 47-100436-05 control board for air handlers with PSC motors. OEM replacement for Rheem and Ruud air handlers. Manages blower motor speed and timing.

Goodman B1376857 motor mount arms, set of 3. OEM replacement for Goodman and Amana furnaces and air handlers. Secures the blower motor in the housing.

Goodman B1376851 motor belly band. Wraps around the blower motor to hold it in place inside the blower housing. OEM Goodman/Amana part.

Motor module adapter — converts 16-pin connector to 4-pin for Genteq Evergreen VS or model 3.0 ECM motors. Required when replacing a GE 2.5 ECM with a newer Evergreen.

Supco ECMPRO universal ECM motor tester. 24 VAC powered with 24-inch leads, magnetic case, and short circuit protection. Tests most ECM blower motors without the furnace board.

1/2″ to 5/8″ motor shaft bushing. Adapts a 1/2″ motor shaft to fit a 5/8″ bore blower wheel or pulley. Steel with keyway slot.

Aftermarket inducer motor for Goodman furnaces. 115V, 3000 RPM, 1/40 HP. Replaces B1859005. Complete assembly with motor, wheel, housing, and gasket.

Aftermarket inducer motor for Lennox furnaces. 120V, 3000 RPM, 1/60 HP. Replaces 85L49. Complete assembly with motor, wheel, housing, and gaskets.

3-leg rigid blower motor bracket for 5.5″ motors. York OEM replacement. Includes rubber grommets and mounting hardware for reduced vibration.

3-leg rigid motor bracket for 5.5″-5.625″ blower motors up to 3/4 HP. Includes rubber grommets and hardware. Universal fit for most furnace and air handler installs.

Packard 66753 inducer motor assembly for Carrier furnaces. Replaces 318984-753. Complete assembly with motor, bracket, and blower wheel — everything you need for a full swap.

Aftermarket inducer motor assembly for Carrier furnaces. 115V, 3200 RPM. Direct replacement for 310371-752. Includes motor, housing, wheel, and gasket — complete swap.

10″ x 10″ clockwise blower wheel with convex blades and 1/2″ bore. Direct replacement for Goodman B1368047A and Rheem RBW10215. Galvanized steel construction.

Rheem 47-100436-84J blower control board for Rheem and Ruud air handlers. OEM replacement — also listed as 47-100436-04. Controls blower motor speed and airflow.

1 HP Genteq Evergreen variable-speed ECM blower motor. 120/240V dual voltage, 4-pin control. Direct drop-in for Genteq model 3.0 ECMs. Largest HP in the Evergreen VS line.

1/2 HP Genteq Evergreen variable-speed ECM blower motor. 120/240V dual voltage, 4-pin control. Direct drop-in for Genteq model 3.0 ECMs. Preprogrammed with harness included.

3-arm flexible motor bracket for 5.5″ diameter blower motors up to 1/2 HP. Supco MB55. Reduces vibration and noise. Includes hardware.

24V DPDT heat sequencer (2 switches). Supco Q103. Controls a heating element and a blower motor on timed delays. Replaces 24A34-3.

Nordyne 1016380R control board. OEM replacement for Nordyne, Miller, and Intertherm air handlers. Replaces 624735-B. Controls blower motor and system functions.

Lennox 94W83 (103085-03) ignition control board. OEM replacement for single-stage Lennox furnaces with PSC blower motors. Direct factory fit.

3/4 HP Genteq Evergreen variable-speed ECM blower motor. 120/240V dual voltage, 1050 RPM, 4-pin control. Direct replacement for Genteq 2.3 and 3.0 ECM motors.

Rheem R801T1005A21UHSNAS gas furnace, 100,000 BTU, 80% AFUE, 21″ cabinet. Constant torque ECM blower motor with PlusOne diagnostics. Upflow/horizontal install. SEER2 compliant.